LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly A1463

Lignum ID-№
A1463
Catalog number
A.2.03.--
Source of construction assembly
Lignatur X09_07_08_lke_silence12_trocken_45kgschuettung_69db_47db, Year 2014
Base structure
Hollow box element
Paneling
Without covering
Reference fire protection
VKF Brandschutzanwendung Nr. 15421
Construction height
288 mm
Weight
176 kg/m2
U-value
≈ 0.321 W/m2K
GWP
0.00 kg CO2-eq/m2
Type sound insulation
Measurement
Ceiling consisting of a basic construction of hollow box element, without sheathing, without ceiling covering, with dampening in supporting structure, without cavity insulation in the supporting structure. With dampening on the supporting structure, with impact sound insulation with a dynamic stiffness [s'] of 15 MN/m³ and with dry screed.
Values of airborne sound insulation
Rw 69 dB
C -4 dB
C50-3150 -10 dB
Values of footfall sound insulation
Ln,w 47 dB
CI 1 dB
CI50-2500 5 dB

Graphic

On-lying material: SWISSSPAN P2 ECO Verlegeplatten
Impact sound insulation: Akustic EP2
Dampening on Supporting structure: Dampening gravel ≤ 1400 kg/m³
Sub-floor: Lignatur box-element sheathing above
Supporting structure: Lignatur box-element LKE silence12
Dampening in supporting structure: Damper and limestone granules LKE silence12
Lower skin layer 1: Lignatur box-element sheathing below

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
On-lying material SWISSSPAN P2 ECO Verlegeplatten Willisauerstrasse 37, Label swiss wood 28 mm - - - 07.015 91.145
Impact sound insulation Akustic EP2 Isover 30 mm 2.1 kg/m2 - - 10.001.01 91.173
Dampening on Supporting structure Dampening gravel ≤ 1400 kg/m³ Fermacell, Zisola 30 mm 42 kg/m2 - - 03.011 91.062
Sub-floor Lignatur box-element sheathing above Lignatur 31 mm 15.2 kg/m2 - - 07.011.01 91.052
Supporting structure Lignatur box-element LKE silence12 Lignatur 138 mm 4.9 kg/m2 54 mm 200 mm 07.011.01 91.052
Dampening in supporting structure Damper and limestone granules LKE silence12 Lignatur 88 mm 97.3 kg/m2 - - 03.011 91.062
Lower skin layer 1 Lignatur box-element sheathing below Lignatur 31 mm 15.2 kg/m2 - - 07.011.01 91.052

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement LSW Stephanskirchen bei Rosenheim 28 26 35 41 47 48 56 61 65 68 72 75 77 79 80 81 82 83 84 85 82
Calculation Lignum/Kühn and Blickle 10 13 16 18 21 24 25 25 27 30 33 36 38 41 41 41 41 50 59 66 75 84
Impact sound (Ln) Measurement LSW Stephanskirchen bei Rosenheim 58 61 60 59 58 56 51 50 49 47 45 43 39 34 30 24 18 10 7 7 8
Calculation Lignum/Kühn and Blickle 70 71 71 71 72 73 74 77 78 78 78 78 79 79 82 85 88 82 76 72 66 60

Airborne sound (R)

Loading...

Impact sound (Ln)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
0
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
0
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
0
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
0
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
0
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
0
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
0
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
0
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
0
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
0
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
0
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
0
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
0
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
0
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
0
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
0
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
0
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
0
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
0
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
0
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
0
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
0
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)