Components

Construction assembly D1234

Lignum ID-№
D1234
Catalog number
D.1.03.AW.60.HL_GF/GF
Source of construction assembly
PFL_SER_2024_Außenwand_VHF_Aluminium, Year 2024
Base structure
Stud
Type of facade
Compact facade
Paneling
Without covering
Construction height
304 mm
Weight
81 kg/m2
U-value
≈ 0.163 W/m2K
GWP
37.90 kg CO2-eq/m2
Type sound insulation
Calculation without verification
Outer wall consisting of a basic construction of stud with cavity insulation in the supporting structure. Sheathed outside & interior, on the outside twice sheathed, roomside double sheathed. Without covering with cavity insulation. Compact facade.
Values of airborne sound insulation
Rw 46 dB
C -2 dB
Ctr -7 dB

Graphic

Surface 1: Duropal Xterior Compact F
Cover leftside 2nd layer: Facade membranes
Coupling: Aluminum profile facade substructure
Cavity dampening: Wood fiber facade insulation board ≥ 180kg/m³
Sheathed outside leftside 2nd layer: GKFI/DFH2IR Knauf Diamant hard- plasterboard
Sheathed outside leftside 1st layer: StyleBoard MDF.RWH
Bond: Stiff, execution of the prior art.
Support: Finger-jointed solid wood width = 60mm
Cavity dampening: Cellulose insulation CLIMACELL
Bond: Rigid, execution of the prior art.
Sheathed rightside 1st layer: LivingBoard P5
Sheathed rightside 2nd layer: Plasterboard type A

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Surface 1 Duropal Xterior Compact F Pfleiderer 8 mm 11.2 kg/m2 - - - -
Cover leftside 2nd layer Facade membranes Generic product 0.4 mm 0.3 kg/m2 - - 09.008 91.037
Coupling Aluminum profile facade substructure Fermacell, Knauf, Rigips, Protektor 80 mm - - - 06.002 91.141
Cavity dampening Wood fiber facade insulation board ≥ 180kg/m³ Gutex, Isover 60 mm 10.8 kg/m2 - - 10.009 91.051
Sheathed outside leftside 2nd layer GKFI/DFH2IR Knauf Diamant hard- plasterboard Knauf 12.5 mm 13.8 kg/m2 - - 03.007 91.063
Sheathed outside leftside 1st layer StyleBoard MDF.RWH Pfleiderer 16 mm 9.6 kg/m2 - - 07.012 91.050
Bond Stiff, execution of the prior art. - - - - - - -
Support Finger-jointed solid wood width = 60mm General Informations, Generic product, August Brühwiler, Dahinden Sägewerk, Filippi, Necker Holz, Schilliger Holz, Origin mark Swiss wood 160 mm 7.5 kg/m2 60 mm 625 mm 07.011 91.052
Cavity dampening Cellulose insulation CLIMACELL Catolet 160 mm 8.8 kg/m2 - - 10.010 91.046
Bond Rigid, execution of the prior art. - - - - - - -
Sheathed rightside 1st layer LivingBoard P5 Pfleiderer 15 mm 10.5 kg/m2 - - 07.015 91.145
Sheathed rightside 2nd layer Plasterboard type A Knauf, Rigips 12.5 mm 9.2 kg/m2 - - 03.008 91.064

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement MFPA Leipzig 27 23 26 26 27 27 28 37 38 40 43 45 49 52 55 56 54 51 54 60 65
Calculation Lignum/Kühn and Blickle 15 18 20 23 26 28 30 30 32 35 38 41 43 45 46 46 46 55 64 71 80 89

Airborne sound (R)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
66021
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
57242.8
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
8843
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
402.3
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
395
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
189.8
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
205.1
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
8
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
229.2
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
228.8
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
52
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
176.7
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
1
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
173.5
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
165.9
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
137.6
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
28.3
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
7.5
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
37.9
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
33.2
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
4.7
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
74.43333333333334
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
20.3
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)