LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly C0107

Lignum ID-№
C0107
Catalog number
C.3.03.D16
Source of construction assembly
Lignum, Year 2016
Base structure
Solid wood panel
Sheathing
without sheathing
Paneling
Covering on one side
Reference fire protection
Lignum Dok. 4.1, Tabelle: 44X
Construction height
195 mm
Weight
73 kg/m2
U-value
≈ 0.278 W/m2K
GWP
123.90 kg CO2-eq/m2
Type sound insulation
Verified calculation
Partition wall single shellconsisting of a basic construction ofsolid timber without cavity insulation in the supporting structure. without sheathing. Covering on one side with cavity insulation.
Values of airborne sound insulation
Rw 57 dB
C -2 dB
C50-3150 -8 dB

Graphic

Support: Wood panel for structural purposes, Cross laminated timber, laminated timber ≥ 450 kg/m³
Coupling: Air
Battens / profiles: CW-wall profile b=50mm
Cavity dampening: Fiber insulation with 5≤ r ≤50 [kPa * s/m]
Covering rightside1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Covering rightside 2nd layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface rightside: Glued joints/smoothed

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Support Wood panel for structural purposes, Cross laminated timber, laminated timber ≥ 450 kg/m³ Willisauerstrasse 37, Pius Schuler, Stora Enso, Binderholz, Novatop, Pfleiderer, Kaufmann Oberholzer, Tschopp, Sidler Holz, Egg Holz Kälin, Schilliger Holz 80 mm 37.6 kg/m2 1000 mm 1000 mm 07.003.01 91.047
Coupling Air - 10 mm - - - - -
Battens / profiles CW-wall profile b=50mm Fermacell, Knauf, Rigips, Protektor 75 mm 1.7 kg/m2 50 mm 625 mm 06.011 91.143
Cavity dampening Fiber insulation with 5≤ r ≤50 [kPa * s/m] Flumroc, Isover, Sager, Swisspor, Gutex, Isofloc, Schilliger Holz 60 mm 1.9 kg/m2 - - 10.008 91.173
Covering rightside1st layer Gypsum fiber or hard gypsum board ≥ 1000kg/m³ Fermacell, Knauf, Rigips 15 mm 16 kg/m2 - - 03.007 91.063
Covering rightside 2nd layer Gypsum fiber or hard gypsum board ≥ 1000kg/m³ Fermacell, Knauf, Rigips 15 mm 16 kg/m2 - - 03.007 91.063
Surface rightside Glued joints/smoothed Fermacell, Knauf, Rigips - - - - - -

Ecological indicators according to the KBOB life cycle assessment data in the construction sector KBOB / ecobau / IPB 2009/1:2022, Version 6
(For the life cycle phases production and disposal, excluding the construction phase (Modules A4, A5) and the use phase (Module B), especially replacement (Module B4) or amortization periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
378299
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
372984
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
5519
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
798.20
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
791.60
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
596.40
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
195.10
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
7.10
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
337.20
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
336.60
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
144.90
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
191.80
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.40
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
461.00
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
454.80
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
451.80
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
3.20
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
6.80
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
123.90
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
121.10
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
2.70
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
0.00
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
18.20
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)