Components

Construction assembly A1470

Lignum ID-№
A1470
Catalog number
A.2.03.--
Source of construction assembly
Lignatur x69_68_70_lfe_akustik_silence12_nass_90kgschuettung_71db_43db, Year 2013
Base structure
Hollow box element
Paneling
Without covering
Reference fire protection
VKF Brandschutzanwendung Nr. 15421
Construction height
390 mm
Weight
267 kg/m2
U-value
≈ 0.295 W/m2K
GWP
0.00 kg CO2-eq/m2
Type sound insulation
Measurement
Ceiling consisting of a basic construction of hollow box element, without sheathing, without ceiling covering, with dampening in supporting structure, without cavity insulation in the supporting structure. With dampening on the supporting structure, with impact sound insulation with a dynamic stiffness [s'] of 0.2 MN/m³ and with cement screed.
Values of airborne sound insulation
Rw 71 dB
C -1 dB
C50-3150 -10 dB
Values of footfall sound insulation
Ln,w 43 dB
CI 0 dB
CI50-2500 2 dB

Graphic

On-lying material: Cement screed
Impact sound insulation: Akustic EP1
Dampening on Supporting structure: Dampening elastic bound gravel ≤ 1400 kg/m³
Sub-floor: Lignatur surface element sheathing above
Supporting structure: Lignatur surface element LFE silence12
Dampening in supporting structure: Damper LFE silence12
Lower skin layer 1: Lignatur surface element acoustics type sheathing below 3

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
On-lying material Cement screed Generic product 50 mm 110 kg/m2 - - 04.006 91.136
Impact sound insulation Akustic EP1 Isover 40 mm 2.8 kg/m2 - - 10.001.01 91.173
Dampening on Supporting structure Dampening elastic bound gravel ≤ 1400 kg/m³ Generic product 60 mm 84 kg/m2 - - 03.011 91.062
Sub-floor Lignatur surface element sheathing above Lignatur 31 mm 14.6 kg/m2 - - 07.011.01 91.052
Supporting structure Lignatur surface element LFE silence12 Lignatur 178 mm 1.4 kg/m2 31 mm 242 mm 07.011.01 91.052
Dampening in supporting structure Damper LFE silence12 Lignatur 135 mm 39.8 kg/m2 - - 03.011 91.062
Lower skin layer 1 Lignatur surface element acoustics type sheathing below 3 Lignatur 31 mm 14.6 kg/m2 - - 07.011.01 91.052

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement LSW Stephanskirchen bei Rosenheim 23 31 45 49 57 58 64 67 62 60 66 70 72 75 79 81 82 82 84 84 82
Calculation Lignum/Kühn and Blickle 17 19 22 25 27 30 32 31 34 37 39 42 45 47 47 47 48 57 65 72 81 90
Impact sound (Ln) Measurement LSW Stephanskirchen bei Rosenheim 56 47 45 45 45 47 45 45 50 53 47 45 44 43 37 33 28 20 14 10 8
Calculation Lignum/Kühn and Blickle 64 65 65 65 66 66 67 71 71 71 72 72 72 73 76 79 81 75 70 66 60 54

Airborne sound (R)

Loading...

Impact sound (Ln)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
0
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
0
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
0
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
0
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
0
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
0
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
0
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
0
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
0
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
0
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
0
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
0
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
0
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
0
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
0
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
0
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
0
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
0
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
0
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
0
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
0
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
0
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)