LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly F0128

Lignum ID-№
F0128
Catalog number
F.1.00.HobelwerkDachTyp1
Source of construction assembly
Baltenperger, Hobelwerk Oberwinterthur, Year 2024
Base structure
Ribs / rafters
Sheathing
Sheathed on the leftside
Paneling
Without covering
Reference fire protection
VKF 14-15, Kap. 3.3 / Lignum Doc. 2.1, Kap. 6
Construction height
425 mm
Weight
63 kg/m2
U-value
≈ 0.229 W/m2K
GWP
141.80 kg CO2-eq/m2
Type sound insulation
Calculation
Flat roof / shed roof consisting of a basic construction of ribs / rafters without cavity insulation in the supporting structure. Sheathed on the leftside, leftside double sheathed . Without covering without insulation on top of the sub-floor.
Values of airborne sound insulation
Rw dB
C dB
Ctr dB
Values of footfall sound insulation
Ln,w dB
CI dB
CI50-2500 dB

Graphic

Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Sheathed above 2nd layer: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Sheathed above 1st layer: ESB Plus P4
Bond: no composite action
Support: Solid wood beams made from softwood

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Use and protection layer 2 Blowing clay Generic product 100 mm - - - 02.004 91.136
Use and protection layer 1 Protective layer Generic product 10 mm 9.2 kg/m2 - - 09.007 91.037
Seal Bituminous geomembrane Generic product 20 mm 22 kg/m2 - - 09.003 91.172
Sheathed above 2nd layer Thermal insulation material with compressive strength ≥50kPa according to EN 826 Gutex, Isover 160 mm 17.6 kg/m2 - - 10.009 91.051
Sheathed above 1st layer ESB Plus P4 Elka Holzwerke 15 mm 9.3 kg/m2 - - 07.015 91.145
Bond no composite action - - - - - - -
Support Solid wood beams made from softwood Generic product, Label swiss wood 120 mm 5.6 kg/m2 60 mm 625 mm 07.011 91.052

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Calculation Lignum/Kühn and Blickle 12 14 17 20 22 25 27 26 29 32 34 37 40 42 43 42 43 52 60 68 77 85
Impact sound (Ln) Calculation Lignum/Kühn and Blickle 69 70 70 70 71 71 72 76 76 76 77 77 77 78 80 84 86 80 75 71 64 59

Airborne sound (R)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
195022.7
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
110497.3
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
84648.1
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
801.4
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
789.7
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
346.7
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
441.3
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
12.6
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
214
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
213.3
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
59.9
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
153.4
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.7
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
587.1
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
574.6
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
287.4
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
288
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
11.8
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
141.8
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
63.4
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
78.4
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
51.7
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
14.1
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)