LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly A1105

Lignum ID-№
A1105
Catalog number
A.3.03.O28
Source of construction assembly
Lignum, Year 2016
Base structure
Solid wood panel
Paneling
Without covering
Reference fire protection
Lignum Dok. 4.1 / Tabelle: 434/5/6
Construction height
420 mm
Weight
390 kg/m2
U-value
≈ 0.257 W/m2K
GWP
36.80 kg CO2-eq/m2
Type sound insulation
Verified calculation
Ceiling consisting of a basic construction of solid timber, without sheathing, without ceiling covering, without dampening in the supporting structure, without cavity insulation in the supporting structure. With dampening on the supporting structure, with impact sound insulation with a dynamic stiffness [s'] of 6 MN/m³ and with anhydrite screed.
Values of airborne sound insulation
Rw 70 dB
C -2 dB
C50-3150 -7 dB
Values of footfall sound insulation
Ln,w 45 dB
CI 0 dB
CI50-2500 5 dB

Graphic

On-lying material: Anhydrite
Impact sound insulation: Glass wool with dynamic stiffness s' of ≤ 6 [MN/m³]
Dampening on Supporting structure: Dampening gravel ≤ 1400 kg/m³
Sub-floor: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Bond: Stiff, execution of the prior art.
Supporting structure: Wood panel for structural purposes, Cross laminated timber, laminated timber ≥ 450 kg/m³

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
On-lying material Anhydrite Generic product 55 mm 110 kg/m2 - - 04.005 91.136
Impact sound insulation Glass wool with dynamic stiffness s' of ≤ 6 [MN/m³] Isover, Sager, Swisspor, Zisola 30 mm 2.4 kg/m2 - - 10.001.01 91.173
Dampening on Supporting structure Dampening gravel ≤ 1400 kg/m³ Fermacell, Zisola 120 mm 168 kg/m2 - - 03.011 91.062
Sub-floor Gypsum fiber or hard gypsum board ≥ 1000kg/m³ Fermacell, Knauf, Rigips 15 mm 16 kg/m2 - - 03.007 91.063
Bond Stiff, execution of the prior art. - - - - - - -
Supporting structure Wood panel for structural purposes, Cross laminated timber, laminated timber ≥ 450 kg/m³ Willisauerstrasse 37, Pius Schuler, Stora Enso, Binderholz, Novatop, Pfleiderer, Kaufmann Oberholzer, Tschopp, Sidler Holz, Egg Holz Kälin, Schilliger Holz 200 mm 94 kg/m2 1000 mm 1000 mm 07.011.02 91.052

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement Lignum Berechnung 31 32 39 44 46 52 57 62 67 72 77 81 86 90 95 100 105 110 110
Calculation Lignum/Kühn and Blickle 34 36 39 42 44 47 49 48 45 47 44 47 50 52 52 52 53 62 70 77 86 95
Impact sound (Ln) Measurement Lignum Berechnung 58 60 56 54 55 52 50 48 46 44 42 41 39 38 36 34 32 28 24
Calculation Lignum/Kühn and Blickle 47 48 48 48 49 49 50 54 60 61 67 67 67 68 71 74 76 70 65 61 54 49

Airborne sound (R)

Loading...

Impact sound (Ln)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
93307.7
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
74462.8
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
18762.9
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
1102.7
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
1076.5
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
578.3
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
502.9
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
25.8
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
950
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
948.4
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
445.5
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
502.9
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
1.3
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
157.1
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
132.6
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
132.6
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
0
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
24.5
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
36.8
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
29.2
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
7.6
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
158.03333333333333
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
43.1
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)