LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly A1349

Lignum ID-№
A1349
Catalog number
A.4.01.A30
Source of construction assembly
Lignum, Year 2016
Base structure
Timber-concrete composite floor (tccf)
Paneling
Without covering
Reference fire protection
Lignum Dok. 4.1 / Tabelle: 437
Construction height
355 mm
Weight
462 kg/m2
U-value
≈ 0.260 W/m2K
GWP
74.10 kg CO2-eq/m2
Type sound insulation
Verified calculation
Ceiling consisting of a basic construction of timber-concrete composite floor (tccf), without sheathing, without ceiling covering, without dampening in the supporting structure, without cavity insulation in the supporting structure. With dampening on the supporting structure, with impact sound insulation with a dynamic stiffness [s'] of 6 MN/m³ and with anhydrite screed.
Values of airborne sound insulation
Rw 69 dB
C -2 dB
C50-3150 -7 dB
Values of footfall sound insulation
Ln,w 46 dB
CI 0 dB
CI50-2500 5 dB

Graphic

On-lying material: Anhydrite
Impact sound insulation: Glass wool with dynamic stiffness s' of ≤ 6 [MN/m³]
Additional insulation: Glass wool with dynamic stiffness s' of ≤ 9 [MN/m³]
Dampening on Supporting structure: Concrete 120mm with reinforcing steel 150mm d=7mm
Bond: Stiff, execution of the prior art.
Supporting structure: Wood panel for structural purposes, Cross laminated timber, laminated timber ≥ 450 kg/m³

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
On-lying material Anhydrite Generic product 55 mm 110 kg/m2 - - 04.005 91.136
Impact sound insulation Glass wool with dynamic stiffness s' of ≤ 6 [MN/m³] Isover, Sager, Swisspor, Zisola 30 mm 2.4 kg/m2 - - 10.001.01 91.173
Additional insulation Glass wool with dynamic stiffness s' of ≤ 9 [MN/m³] Isover, Sager, Swisspor, Zisola 30 mm 2.4 kg/m2 - - 10.001.01 91.173
Dampening on Supporting structure Concrete 120mm with reinforcing steel 150mm d=7mm Generic product 120 mm 291.7 kg/m2 - - 01.042 91.061
Bond Stiff, execution of the prior art. - - - - - - -
Supporting structure Wood panel for structural purposes, Cross laminated timber, laminated timber ≥ 450 kg/m³ Willisauerstrasse 37, Pius Schuler, Stora Enso, Binderholz, Novatop, Pfleiderer, Kaufmann Oberholzer, Tschopp, Sidler Holz, Egg Holz Kälin, Schilliger Holz 120 mm 56.4 kg/m2 1000 mm 1000 mm 07.011.02 91.052

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement Lignum Berechnung 30 36 42 47 48 54 59 63 69 74 79 83 87 92 97 101 106 110 110
Calculation Lignum/Kühn and Blickle 33 36 39 42 44 47 48 48 50 53 56 59 61 64 64 64 64 73 82 89 98 106
Impact sound (Ln) Measurement Lignum Berechnung 59 56 53 51 52 51 48 46 44 42 40 39 38 36 34 33 31 26 22
Calculation Lignum/Kühn and Blickle 47 48 48 48 49 49 51 54 55 55 55 55 56 56 59 62 65 59 53 49 43 38

Airborne sound (R)

Loading...

Impact sound (Ln)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
138951
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
120173.4
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
18668.7
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
826.5
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
799.4
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
500.5
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
301.7
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
27.1
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
605
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
603.6
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
301.9
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
301.7
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
1.2
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
224.2
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
198.4
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
198.4
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
0
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
25.9
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
74.09999999999998
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
66.7
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
7.4
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
93.13333333333333
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
25.4
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)