LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly A0229

Lignum ID-№
A0229
Catalog number
A.1.03.A52
Source of construction assembly
Lignum, Year 2016
Base structure
Ribs / joists
Paneling
Without covering
Reference fire protection
Lignum Dok. 4.1 / Tabelle: 431 (Balken) oder 432 (Rippen)
Construction height
410 mm
Weight
194 kg/m2
U-value
≈ 0.422 W/m2K
GWP
46.60 kg CO2-eq/m2
Type sound insulation
Verified calculation
Ceiling consisting of a basic construction of ribs / joists, without sheathing, without ceiling covering, without dampening in the supporting structure, without cavity insulation in the supporting structure. With dampening on the supporting structure, with impact sound insulation with a dynamic stiffness [s'] of 30 MN/m³ and with dry screed.
Values of airborne sound insulation
Rw 53 dB
C -3 dB
C50-3150 -3 dB
Values of footfall sound insulation
Ln,w 62 dB
CI 0 dB
CI50-2500 1 dB

Graphic

On-lying material: Floor heating system Therm38 longitudinal grooves
Impact sound insulation: Wood fiber with dynamic stiffness s' of ≤ 30 [MN / m²]
Dampening on Supporting structure: Cement panels, glued on sub-floor
Sub-floor: Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
On-lying material Floor heating system Therm38 longitudinal grooves Fermacell, Knauf, Rigips 23 mm 28.3 kg/m2 - - 03.007 91.063
Impact sound insulation Wood fiber with dynamic stiffness s' of ≤ 30 [MN / m²] Gutex, Isover 22 mm 3.5 kg/m2 - - 10.009 91.051
Dampening on Supporting structure Cement panels, glued on sub-floor Generic product 60 mm 120 kg/m2 - - 02.007 91.136
Sub-floor Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³ Willisauerstrasse 37, Pius Schuler, Stora Enso, Binderholz, Novatop, Pfleiderer, Schilliger Holz 25 mm 11.8 kg/m2 - - 07.001 91.048
Bond Stiff, execution of the prior art. - - - - - - -
Supporting structure Rib/bar Generic product, Label swiss wood 280 mm 30.7 kg/m2 140 mm 625 mm 07.003.01 91.047

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement Lignum Berechnung 26 29 31 32 30 32 37 43 49 55 60 64 69 73 78 83 88 95 103
Calculation Lignum/Kühn and Blickle 25 27 30 33 35 38 40 39 42 45 47 50 53 55 55 55 56 65 73 80 90 98
Impact sound (Ln) Measurement Lignum Berechnung 62 63 64 66 71 72 70 66 64 61 59 58 56 54 52 51 49 44 40
Calculation Lignum/Kühn and Blickle 56 57 57 57 58 58 59 63 63 64 64 64 64 65 68 71 73 67 62 58 51 46

Airborne sound (R)

Loading...

Impact sound (Ln)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
88101.7
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
77059.7
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
11133.4
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
603.9
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
590.4
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
349.7
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
241.7
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
13.6
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
433.4
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
432.7
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
199
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
233.1
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.7
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
171.4
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
158.6
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
150.2
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
8.4
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
12.9
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
46.6
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
42.1
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
4.5
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
79.2
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
21.6
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)