LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly A0227

Lignum ID-№
A0227
Catalog number
A.1.03.A32
Source of construction assembly
Lignum, Year 2016
Base structure
Ribs / joists
Paneling
Without covering
Reference fire protection
Lignum Dok. 4.1 / Tabelle: 431 (Balken) oder 432 (Rippen)
Construction height
480 mm
Weight
277 kg/m2
U-value
≈ 0.300 W/m2K
GWP
43.40 kg CO2-eq/m2
Type sound insulation
Verified calculation
Ceiling consisting of a basic construction of ribs / joists, without sheathing, without ceiling covering, without dampening in the supporting structure, without cavity insulation in the supporting structure. With dampening on the supporting structure, with impact sound insulation with a dynamic stiffness [s'] of 6 MN/m³ and with anhydrite screed.
Values of airborne sound insulation
Rw 66 dB
C -3 dB
C50-3150 -7 dB
Values of footfall sound insulation
Ln,w 49 dB
CI 0 dB
CI50-2500 5 dB

Graphic

On-lying material: Anhydrite
Impact sound insulation: Glass wool with dynamic stiffness s' of ≤ 6 [MN/m³]
Additional insulation: Glass wool with dynamic stiffness s' of ≤ 9 [MN/m³]
Dampening on Supporting structure: Cement panels, glued on sub-floor
Sub-floor: Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
On-lying material Anhydrite Generic product 55 mm 110 kg/m2 - - 04.005 91.136
Impact sound insulation Glass wool with dynamic stiffness s' of ≤ 6 [MN/m³] Isover, Sager, Swisspor, Zisola 30 mm 2.4 kg/m2 - - 10.001.01 91.173
Additional insulation Glass wool with dynamic stiffness s' of ≤ 9 [MN/m³] Isover, Sager, Swisspor, Zisola 30 mm 2.4 kg/m2 - - 10.001.01 91.173
Dampening on Supporting structure Cement panels, glued on sub-floor Generic product 60 mm 120 kg/m2 - - 02.007 91.136
Sub-floor Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³ Willisauerstrasse 37, Pius Schuler, Stora Enso, Binderholz, Novatop, Pfleiderer, Schilliger Holz 25 mm 11.8 kg/m2 - - 07.001 91.048
Bond Stiff, execution of the prior art. - - - - - - -
Supporting structure Rib/bar Generic product, Label swiss wood 280 mm 30.7 kg/m2 140 mm 625 mm 07.003.01 91.047

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement Lignum Berechnung 25 29 36 41 43 48 53 58 63 68 73 77 82 86 91 96 101 108 110
Calculation Lignum/Kühn and Blickle 28 30 33 36 38 41 43 42 45 47 50 53 56 58 58 58 59 67 76 83 92 101
Impact sound (Ln) Measurement Lignum Berechnung 63 63 59 57 58 56 54 52 50 48 46 45 43 42 40 38 36 32 28
Calculation Lignum/Kühn and Blickle 53 54 54 54 55 55 56 60 60 61 61 61 61 62 65 68 70 64 59 55 48 43

Airborne sound (R)

Loading...

Impact sound (Ln)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
90910.5
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
77373.8
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
13543.4
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
580.5
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
563
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
342.4
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
221.7
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
17.4
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
420.1
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
419.2
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
203.7
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
214.9
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.8
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
161.3
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
144.7
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
138.3
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
6.6
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
16.6
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
43.4
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
38.1
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
5.4
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
68.93333333333334
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
18.8
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)