Components

Construction assembly A2103

Lignum ID-№
A2103
Catalog number
A.3.01.DE220A
Source of construction assembly
Tschopp, Year 2017
Base structure
BRESTA Solid Timber System
Paneling
Substructure rigid screwed
Reference fire protection
Lignum Dok. 4.1 / Tabelle: 434
Construction height
201 mm
Weight
138 kg/m2
U-value
≈ 0.401 W/m2K
GWP
24.30 kg CO2-eq/m2
Type sound insulation
Calculation
Ceiling consisting of a basic construction of BRESTA Solid Timber System, without sheathing, simple ceiling covering. stiff screwed substructure, without dampening in the supporting structure, without cavity insulation in the supporting structure. With dampening on the supporting structure, with impact sound insulation with a dynamic stiffness [s'] of 120 MN/m³ and with dry screed.
Values of airborne sound insulation
Rw 52 dB
C -2 dB
C50-3150 -1 dB
Values of footfall sound insulation
Ln,w 63 dB
CI 0 dB
CI50-2500 1 dB

Graphic

Flooring: Fllor
On-lying material: Gypsum fiber board ≥ 1000kg/m³
Impact sound insulation: Wood fiber generic product
Dampening on Supporting structure: Cardboard with broken grains
Sub-floor: Trickling protection
Bond: no composite action
Supporting structure: Bresta Solid timber panel
Bond: Stiff, execution of the prior art.
Battens / profiles: Wood lath transversely b=60mm
Ceiling covering 1st layer: Plasterboard type A
Surface / treatment: Innenputz, verspachtelt

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Flooring Fllor Generic product 15 mm 15 kg/m2 - - 11.013 91.011
On-lying material Gypsum fiber board ≥ 1000kg/m³ Fermacell, Knauf, Rigips 20 mm 21.3 kg/m2 - - 03.007 91.063
Impact sound insulation Wood fiber generic product Generic product 10 mm 1.6 kg/m2 - - 10.009 91.051
Dampening on Supporting structure Cardboard with broken grains Fermacell 30 mm 45 kg/m2 - - - -
Sub-floor Trickling protection Generic product 0.5 mm 0.4 kg/m2 - - 09.007 91.037
Bond no composite action - - - - - - -
Supporting structure Bresta Solid timber panel Tschopp 80 mm 39.2 kg/m2 1000 mm 1000 mm 07.011.02 91.052
Bond Stiff, execution of the prior art. - - - - - - -
Battens / profiles Wood lath transversely b=60mm Generic product, Origin mark Swiss wood 30 mm 2.2 kg/m2 60 mm 400 mm 07.011 91.052
Ceiling covering 1st layer Plasterboard type A Knauf, Rigips 12.5 mm 9.2 kg/m2 - - 03.008 91.064
Surface / treatment Innenputz, verspachtelt Fermacell, Knauf, Rigips 3 mm 4.2 kg/m2 - - 04.001 91.139

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Calculation Lignum/Kühn and Blickle 20 22 25 28 30 33 35 34 36 39 41 42 43 44 52 61 67 74 81 87 95 104
Impact sound (Ln) Calculation Lignum/Kühn and Blickle 61 62 62 62 63 63 64 68 69 69 70 71 74 76 71 65 62 58 55 51 45 40

Airborne sound (R)

Loading...

Impact sound (Ln)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
47693.2
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
41188.5
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
6510.1
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
521.9
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
514.8
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
281.4
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
235.3
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
7
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
419.8
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
419.2
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
189.7
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
229.5
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.4
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
103.9
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
97.3
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
91.5
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
5.8
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
6.6
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
24.3
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
20.8
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
3.5
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
75.16666666666667
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
20.5
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)