Components

Construction assembly A2279

Lignum ID-№
A2279
Catalog number
A.2.01.Eggo17-3
Source of construction assembly
Egg Holz Kälin, Year 2017
Base structure
Hollow box element
Paneling
Without covering
Reference fire protection
Download: Katalog werkstoffoptimierter Bauteile von Eggo (PDF)
Construction height
335 mm
Weight
338 kg/m2
U-value
≈ 0.324 W/m2K
GWP
32.60 kg CO2-eq/m2
Type sound insulation
Measurement
Ceiling consisting of a basic construction of hollow box element, without sheathing, without ceiling covering, with dampening in supporting structure, without cavity insulation in the supporting structure. With dampening on the supporting structure, with impact sound insulation with a dynamic stiffness [s'] of 5.7 MN/m³ and with cement screed.
Values of airborne sound insulation
Rw 81 dB
C -4 dB
C50-3150 -19 dB
Values of footfall sound insulation
Ln,w 37 dB
CI 0 dB
CI50-2500 11 dB

Graphic

On-lying material: Cement screed
Impact sound insulation: ISOVER PS 81 D = 30/27mm
Additional insulation: OSB panel
Dampening on Supporting structure: Cardboard with broken grains
Sub-floor: Element planking above
Bond: Rigid
Supporting structure: Floor element EB
Dampening in supporting structure: CCN Kalk Körnung 2-3mm
Bond: Rigid, execution of the prior art.
Lower skin layer 1: Element planking below

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
On-lying material Cement screed Mayr-Melnhof Holz 60 mm 150 kg/m2 - - 04.006 91.136
Impact sound insulation ISOVER PS 81 D = 30/27mm Isover 30 mm 2.4 kg/m2 - - 10.001.01 91.173
Additional insulation OSB panel Willisauerstrasse 37, Pius Schuler, Stora Enso, Binderholz, Novatop, Pfleiderer 15 mm 9.8 kg/m2 - - 07.013 91.145
Dampening on Supporting structure Cardboard with broken grains Fermacell 30 mm 45 kg/m2 - - - -
Sub-floor Element planking above Egg Holz Kälin 30.5 mm 14.9 kg/m2 - - 07.011.01 91.052
Bond Rigid - - - - - - -
Supporting structure Floor element EB Egg Holz Kälin 139 mm 1.1 kg/m2 31 mm 242 mm 07.011 91.052
Dampening in supporting structure CCN Kalk Körnung 2-3mm Generic product 79.3 mm 100.3 kg/m2 - - 03.011 91.062
Bond Rigid, execution of the prior art. - - - - - - -
Lower skin layer 1 Element planking below Egg Holz Kälin 30.5 mm 14.9 kg/m2 - - 07.011.01 91.052

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement Holz Forschung Austria 23 33 44 52 58 61 67 73 81 83 86 87 90 95 96 98 99 96 94 94 92
Calculation Lignum/Kühn and Blickle 18 20 23 26 28 31 33 32 35 38 40 43 46 48 48 48 49 57 66 73 82 90
Impact sound (Ln) Measurement Holz Forschung Austria 61 58 48 45 46 45 42 36 30 29 31 34 32 29 29 30 27 20 15 10 7
Calculation Lignum/Kühn and Blickle 63 64 64 64 65 65 66 70 70 71 71 71 71 72 75 78 80 74 69 65 59 54

Airborne sound (R)

Loading...

Impact sound (Ln)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
66082.6
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
52307.8
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
13667.6
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
381.5
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
363.3
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
148.3
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
214.6
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
18
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
276.3
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
275.6
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
66.2
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
209.3
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.8
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
104.7
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
87.5
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
82.3
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
5.2
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
17.2
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
32.6
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
27.2
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
5.3
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
67.10000000000001
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
18.3
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)