Components

Construction assembly A1347

Lignum ID-№
A1347
Catalog number
A.4.01.A10
Source of construction assembly
Lignum, Year 2016
Base structure
Timber-concrete composite floor (tccf)
Paneling
Without covering
Reference fire protection
Lignum Dok. 4.1 / Tabelle: 437
Construction height
380 mm
Weight
528 kg/m2
U-value
≈ 0.259 W/m2K
GWP
85.20 kg CO2-eq/m2
Type sound insulation
Verified calculation
Ceiling consisting of a basic construction of timber-concrete composite floor (tccf), without sheathing, without ceiling covering, without dampening in the supporting structure, without cavity insulation in the supporting structure. With dampening on the supporting structure, with impact sound insulation with a dynamic stiffness [s'] of 6 MN/m³ and with cement screed.
Values of airborne sound insulation
Rw 72 dB
C -3 dB
C50-3150 -7 dB
Values of footfall sound insulation
Ln,w 43 dB
CI 0 dB
CI50-2500 5 dB

Graphic

On-lying material: Cement screed
Impact sound insulation: Glass wool with dynamic stiffness s' of ≤ 6 [MN/m³]
Additional insulation: Glass wool with dynamic stiffness s' of ≤ 9 [MN/m³]
Dampening on Supporting structure: Concrete 120mm with reinforcing steel 150mm d=7mm
Bond: Stiff, execution of the prior art.
Supporting structure: Wood panel for structural purposes, Cross laminated timber, laminated timber ≥ 450 kg/m³

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
On-lying material Cement screed Generic product 80 mm 176 kg/m2 - - 04.006 91.136
Impact sound insulation Glass wool with dynamic stiffness s' of ≤ 6 [MN/m³] Isover, Sager, Swisspor, Zisola 30 mm 2.4 kg/m2 - - 10.001.01 91.173
Additional insulation Glass wool with dynamic stiffness s' of ≤ 9 [MN/m³] Isover, Sager, Swisspor, Zisola 30 mm 2.4 kg/m2 - - 10.001.01 91.173
Dampening on Supporting structure Concrete 120mm with reinforcing steel 150mm d=7mm Generic product 120 mm 291.7 kg/m2 - - 01.042 91.061
Bond Stiff, execution of the prior art. - - - - - - -
Supporting structure Wood panel for structural purposes, Cross laminated timber, laminated timber ≥ 450 kg/m³ Willisauerstrasse 37, Pius Schuler, Stora Enso, Binderholz, Novatop, Pfleiderer, Kaufmann Oberholzer, Tschopp, Sidler Holz, Egg Holz Kälin, Schilliger Holz 120 mm 56.4 kg/m2 1000 mm 1000 mm 07.011.02 91.052

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement Lignum Berechnung 34 40 45 50 51 56 61 66 71 76 81 85 90 94 99 104 109 110 110
Calculation Lignum/Kühn and Blickle 34 37 40 43 45 48 49 49 51 54 57 60 62 65 65 65 65 74 83 90 99 107
Impact sound (Ln) Measurement Lignum Berechnung 55 52 50 48 50 48 46 44 42 40 38 37 35 34 32 30 28 24 20
Calculation Lignum/Kühn and Blickle 46 47 47 47 48 48 50 53 54 54 54 54 55 55 58 61 64 58 52 48 42 37

Airborne sound (R)

Loading...

Impact sound (Ln)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
151557
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
129941.4
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
21473.7
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
823
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
792.1
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
493.2
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
301.7
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
30.7
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
607.9
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
606.4
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
304.6
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
301.7
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
1.3
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
217.6
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
188.6
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
188.6
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
0
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
29.3
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
85.2
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
76.9
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
8.199999999999998
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
93.13333333333333
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
25.4
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)