LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly A0027

Lignum ID-№
A0027
Catalog number
A.2.03.4168
Source of construction assembly
Lignatur_k08_08 Mess.Nr.X39_40_LKE_Trockenaufbau_61db_61db, Year 2020
Base structure
Hollow box element
Paneling
Without covering
Reference fire protection
VKF Brandschutzanwendung Nr. 15421
Construction height
275 mm
Weight
112 kg/m2
U-value
≈ 0.394 W/m2K
GWP
0.00 kg CO2-eq/m2
Type sound insulation
Measurement
Ceiling consisting of a basic construction of hollow box element, without sheathing, without ceiling covering, without dampening in the supporting structure, without cavity insulation in the supporting structure. With dampening on the supporting structure, with impact sound insulation with a dynamic stiffness [s'] of 37.5 MN/m³ and with dry screed.
Values of airborne sound insulation
Rw 61 dB
C -3 dB
C50-3150 -7 dB
Values of footfall sound insulation
Ln,w 58 dB
CI 0 dB
CI50-2500 1 dB

Graphic

On-lying material: GF-W2 Fermacell gypsum fiber board
Impact sound insulation: GUTEX Thermofloor 20mm
Dampening on Supporting structure: Cardboard with broken grains
Sub-floor: Lignatur box-element sheathing above
Supporting structure: Lignatur box-element LKE
Lower skin layer 1: Lignatur box-element sheathing below

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
On-lying material GF-W2 Fermacell gypsum fiber board Fermacell 25 mm 28.8 kg/m2 - - 03.007 91.063
Impact sound insulation GUTEX Thermofloor 20mm Gutex 20 mm 3.2 kg/m2 - - 10.009 91.051
Dampening on Supporting structure Cardboard with broken grains Fermacell 30 mm 45 kg/m2 - - - -
Sub-floor Lignatur box-element sheathing above Lignatur 31 mm 15.2 kg/m2 - - 07.011.01 91.052
Supporting structure Lignatur box-element LKE Lignatur 138 mm 4.9 kg/m2 54 mm 200 mm 07.011.01 91.052
Lower skin layer 1 Lignatur box-element sheathing below Lignatur 31 mm 15.2 kg/m2 - - 07.011.01 91.052

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement LSW Stephanskirchen bei Rosenheim 19 24 29 33 40 42 48 53 56 55 60 62 67 68 70 72 73 75 77 81 81
Calculation Lignum/Kühn and Blickle 7 9 12 15 17 20 22 21 24 26 29 32 35 37 37 37 38 46 55 62 71 80
Impact sound (Ln) Measurement LSW Stephanskirchen bei Rosenheim 63 65 66 64 64 64 63 64 64 64 61 60 56 55 50 46 42 36 29 22 15
Calculation Lignum/Kühn and Blickle 74 75 75 75 76 76 77 81 82 82 82 82 83 83 86 89 91 85 80 76 70 64

Airborne sound (R)

Loading...

Impact sound (Ln)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
0
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
0
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
0
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
0
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
0
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
0
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
0
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
0
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
0
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
0
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
0
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
0
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
0
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
0
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
0
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
0
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
0
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
0
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
0
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
0
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
0
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
0
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)