LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly D1201

Lignum ID-№
D1201
Catalog number
D.3.03.21001299/W11
Source of construction assembly
21-001299-PRO1 PB W11-F02-04-de-01, Year 2021
Base structure
Solid timber, derived wood products
Type of facade
Compact facade
Paneling
Without covering
Construction height
110 mm
Weight
78 kg/m2
U-value
≈ 0.474 W/m2K
GWP
37.20 kg CO2-eq/m2
Type sound insulation
Measurement
Outer wall consisting of a basic construction of solid timber, derived wood product without cavity insulation in the supporting structure. without sheathing, . Without covering. Compact facade.
Values of airborne sound insulation
Rw 39 dB
C -2 dB
Ctr -3 dB

Graphic

Support: SWISS KRONO MAGNUMBOARD OSB
Bond: Rigid, execution of the prior art.
Surface rightside: Mineral Basecoat, Knauf (Marmorit) SM 700

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Support SWISS KRONO MAGNUMBOARD OSB Willisauerstrasse 37, Wittstocker Chaussee 1 100 mm 66 kg/m2 1000 mm 1000 mm 07.013 91.145
Bond Rigid, execution of the prior art. - - - - - - -
Surface rightside Mineral Basecoat, Knauf (Marmorit) SM 700 Generic product 10 mm 12.3 kg/m2 - - - -

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement Ift Rosenheim 28 26 32 34 36 33 34 33 31 27 31 35 38 41 43 45 46 47 45 45 48
Calculation Lignum/Kühn and Blickle 22 24 26 28 29 29 29 35 38 45 45 52 59 65 70 76 82 88 94 100 108 110

Airborne sound (R)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
67980
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
60852
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
6996
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
726
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
719.4
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
345.2
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
371.6
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
6.9
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
545.2
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
544.5
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
208.6
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
335.9
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.4
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
178.9
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
172.3
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
137.3
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
35.3
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
6.4
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
37.2
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
31.9
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
5.3
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
107.43333333333334
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
29.3
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)