Components

Construction assembly A1097

Lignum ID-№
A1097
Catalog number
A.3.03.A25
Source of construction assembly
Lignum, Year 2016
Base structure
Solid wood panel
Paneling
Without covering
Reference fire protection
Lignum Dok. 4.1 / Tabelle: 434/5/6
Construction height
460 mm
Weight
442 kg/m2
U-value
≈ 0.218 W/m2K
GWP
52.80 kg CO2-eq/m2
Type sound insulation
Verified calculation
Ceiling consisting of a basic construction of solid timber, without sheathing, without ceiling covering, without dampening in the supporting structure, without cavity insulation in the supporting structure. With dampening on the supporting structure, with impact sound insulation with a dynamic stiffness [s'] of 6 MN/m³ and with cement screed.
Values of airborne sound insulation
Rw 75 dB
C -3 dB
C50-3150 -7 dB
Values of footfall sound insulation
Ln,w 40 dB
CI 0 dB
CI50-2500 5 dB

Graphic

On-lying material: Cement screed
Impact sound insulation: Glass wool with dynamic stiffness s' of ≤ 6 [MN/m³]
Additional insulation: Glass wool with dynamic stiffness s' of ≤ 9 [MN/m³]
Dampening on Supporting structure: Dampening gravel ≤ 1400 kg/m³
Supporting structure: Wood panel for structural purposes, Cross laminated timber, laminated timber ≥ 450 kg/m³

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
On-lying material Cement screed Generic product 80 mm 176 kg/m2 - - 04.006 91.136
Impact sound insulation Glass wool with dynamic stiffness s' of ≤ 6 [MN/m³] Isover, Sager, Swisspor, Zisola 30 mm 2.4 kg/m2 - - 10.001.01 91.173
Additional insulation Glass wool with dynamic stiffness s' of ≤ 9 [MN/m³] Isover, Sager, Swisspor, Zisola 30 mm 2.4 kg/m2 - - 10.001.01 91.173
Dampening on Supporting structure Dampening gravel ≤ 1400 kg/m³ Fermacell, Zisola 120 mm 168 kg/m2 - - 03.011 91.062
Supporting structure Wood panel for structural purposes, Cross laminated timber, laminated timber ≥ 450 kg/m³ Swiss Krono, Pius Schuler, Stora Enso, Binderholz, Novatop, Pfleiderer, Kaufmann Oberholzer, Tschopp, Sidler Holz, Egg Holz Kälin, Schilliger Holz 200 mm 94 kg/m2 1000 mm 1000 mm 07.002 91.047

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement Lignum Berechnung 34 40 46 50 51 57 61 66 71 77 81 86 90 95 99 104 109 110 110
Calculation Lignum/Kühn and Blickle 36 39 41 44 47 49 51 51 47 50 47 50 52 54 55 55 55 64 73 80 88 97
Impact sound (Ln) Measurement Lignum Berechnung 55 52 49 48 49 48 45 43 41 39 37 36 35 33 31 30 28 23 19
Calculation Lignum/Kühn and Blickle 45 45 46 46 46 47 48 51 58 58 64 64 65 66 68 71 74 68 63 58 52 47

Airborne sound (R)

Loading...

Impact sound (Ln)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
119940.4
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
98086.8
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
21727.6
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
964
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
935
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
447.1
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
487.9
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
28.7
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
771.6
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
769.9
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
290.5
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
479.4
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
1.4
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
192.3
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
165.2
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
157.7
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
7.9
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
27.3
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
52.8
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
43.5
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
9.3
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
154
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
42
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)