LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly A0014

Lignum ID-№
A0014
Catalog number
A.2.03.--
Source of construction assembly
Novatop Prüfbericht 143/08 (90/08)(91/08), Year 2008
Base structure
Hollow box element
Paneling
Without covering
Reference fire protection
Lignum Dok. 4.1 / Tabelle: 433
Construction height
328 mm
Weight
153 kg/m2
U-value
≈ 0.456 W/m2K
GWP
28.40 kg CO2-eq/m2
Type sound insulation
Measurement
Ceiling consisting of a basic construction of hollow box element, without sheathing, without ceiling covering, without dampening in the supporting structure, without cavity insulation in the supporting structure. With dampening on the supporting structure, with impact sound insulation and with dry screed.
Values of airborne sound insulation
Rw 59 dB
C -2 dB
C50-3150 dB
Values of footfall sound insulation
Ln,w 60 dB
CI 0 dB
CI50-2500 dB

Graphic

On-lying material: GF-W2 Fermacell gypsum fiber board
Impact sound insulation: Steico base
Dampening on Supporting structure: Cardboard with broken grains
Sub-floor: 3-layer board Spruce Nova Top
Bond: Rigid, execution of the prior art.
Supporting structure: Novatop 27x186 mm/s = 320 mm + brace
Bond: Rigid, execution of the prior art.
Lower skin layer 1: 3-layer board Spruce Nova Top

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
On-lying material GF-W2 Fermacell gypsum fiber board Fermacell 20 mm 23 kg/m2 - - 03.007 91.063
Impact sound insulation Steico base STEICO 8 mm 2 kg/m2 - - 10.009 91.051
Dampening on Supporting structure Cardboard with broken grains Fermacell 60 mm 90 kg/m2 - - - -
Sub-floor 3-layer board Spruce Nova Top Kuratle & Jaecker 27 mm 12.7 kg/m2 - - 07.001 91.048
Bond Rigid, execution of the prior art. - - - - - - -
Supporting structure Novatop 27x186 mm/s = 320 mm + brace Novatop 186 mm 13.4 kg/m2 27 mm 320 mm 07.011 91.052
Bond Rigid, execution of the prior art. - - - - - - -
Lower skin layer 1 3-layer board Spruce Nova Top Kuratle & Jaecker 27 mm 12.7 kg/m2 - - 07.001 91.048

Ecological indicators according to the KBOB life cycle assessment data in the construction sector KBOB / ecobau / IPB 2009/1:2022, Version 6
(For the life cycle phases production and disposal, excluding the construction phase (Modules A4, A5) and the use phase (Module B), especially replacement (Module B4) or amortization periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
54887
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
49968
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
4979
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
562.40
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
556.50
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
344.10
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
214.60
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
6.00
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
435.00
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
434.80
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
228.60
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
204.90
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.40
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
129.40
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
123.80
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
114.10
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
9.60
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
5.60
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
28.40
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
25.80
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
2.50
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
69.30
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
18.90
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)