Components

Construction assembly B0303

Lignum ID-№
B0303
Catalog number
B.3.01.IW 960A
Source of construction assembly
Tschopp, Year 2017
Base structure
BRESTA Solid Timber System
Sheathing
Sheathed on both sides
Reference fire protection
Lignum Dok. 4.1 / Tabelle: 444
Construction height
336 mm
Weight
238 kg/m2
U-value
≈ 0.300 W/m2K
GWP
69.00 kg CO2-eq/m2
Type sound insulation
Calculation
Partition wall double shell consisting of a basic construction of solid timber without cavity insulation in the supporting structure. Sheathed interior side & in the interspace.Without covering. Without cavity insulation between the wall panels.
Values of airborne sound insulation
Rw 57 dB
C -2 dB
C50-3150 dB

Graphic

Surface leftside: Innenputz, verspachtelt
Sheathed room side leftside 2nd layer: GKFI/DFH2IR Knauf Diamant hard- plasterboard
Sheathed room side leftside 1st layer: GKFI/DFH2IR Knauf Diamant hard- plasterboard
Bond: Stiff, execution of the prior art.
Support leftside: Bresta Solid timber panel
Bond: Stiff, execution of the prior art.
Sheathed outside leftside 1st layer: GKFI/DFH2IR Knauf Diamant hard- plasterboard
Sheathed outside leftside 2nd layer: GKFI/DFH2IR Knauf Diamant hard- plasterboard
Air gap: Air
Sheathed far rightside 2nd layer: GKFI/DFH2IR Knauf Diamant hard- plasterboard
Sheathed outside rightside 1st layer: GKFI/DFH2IR Knauf Diamant hard- plasterboard
Bond: Stiff, execution of the prior art.
Support rightside: Bresta Solid timber panel
Bond: Stiff, execution of the prior art.
Sheathed room side rightside 1st layer: GKFI/DFH2IR Knauf Diamant hard- plasterboard
Sheathed room side rightside 2nd layer: GKFI/DFH2IR Knauf Diamant hard- plasterboard
Surface rightside: Innenputz, verspachtelt

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Surface leftside Innenputz, verspachtelt Fermacell, Knauf, Rigips 3 mm 4.2 kg/m2 - - 04.001 91.139
Sheathed room side leftside 2nd layer GKFI/DFH2IR Knauf Diamant hard- plasterboard Knauf 15 mm 16.5 kg/m2 - - 03.007 91.063
Sheathed room side leftside 1st layer GKFI/DFH2IR Knauf Diamant hard- plasterboard Knauf 15 mm 16.5 kg/m2 - - 03.007 91.063
Bond Stiff, execution of the prior art. - - - - - - -
Support leftside Bresta Solid timber panel Tschopp 100 mm 49 kg/m2 1000 mm 1000 mm 07.011.02 91.052
Bond Stiff, execution of the prior art. - - - - - - -
Sheathed outside leftside 1st layer GKFI/DFH2IR Knauf Diamant hard- plasterboard Knauf 15 mm 16.5 kg/m2 - - 03.007 91.063
Sheathed outside leftside 2nd layer GKFI/DFH2IR Knauf Diamant hard- plasterboard Knauf 15 mm 16.5 kg/m2 - - 03.007 91.063
Air gap Air - 10 mm - - - - -
Sheathed far rightside 2nd layer GKFI/DFH2IR Knauf Diamant hard- plasterboard Knauf 15 mm 16.5 kg/m2 - - 03.007 91.063
Sheathed outside rightside 1st layer GKFI/DFH2IR Knauf Diamant hard- plasterboard Knauf 15 mm 16.5 kg/m2 - - 03.007 91.063
Bond Stiff, execution of the prior art. - - - - - - -
Support rightside Bresta Solid timber panel Tschopp 100 mm 49 kg/m2 1000 mm 1000 mm 07.011.02 91.052
Bond Stiff, execution of the prior art. - - - - - - -
Sheathed room side rightside 1st layer GKFI/DFH2IR Knauf Diamant hard- plasterboard Knauf 15 mm 16.5 kg/m2 - - 03.007 91.063
Sheathed room side rightside 2nd layer GKFI/DFH2IR Knauf Diamant hard- plasterboard Knauf 15 mm 16.5 kg/m2 - - 03.007 91.063
Surface rightside Innenputz, verspachtelt Fermacell, Knauf, Rigips 3 mm 4.2 kg/m2 - - 04.001 91.139

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Calculation Lignum/Kühn and Blickle 20 21 20 27 36 43 49 52 52 59 59 65 72 78 83 89 94 100 106 110 110 110

Airborne sound (R)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
130591.4
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
116936.6
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
13599.7
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
1279.8
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
1261.7
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
742.3
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
524.4
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
17.9
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
988.3
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
986.9
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
462.5
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
524.4
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
1
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
296
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
279
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
279
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
0
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
16.8
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
69
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
63.2
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
5.8
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
0
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
48.7
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)