LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly D1236

Lignum ID-№
D1236
Catalog number
D.1.04.AW.60.HL_GF/GF
Source of construction assembly
PFL_SER_2024_Außenwand_WDVS_Installation, Year 2024
Base structure
Stud
Type of facade
Compact facade and wall covering
Paneling
Substructure rigid screwed
Construction height
327 mm
Weight
63 kg/m2
U-value
≈ 0.126 W/m2K
GWP
26.20 kg CO2-eq/m2
Type sound insulation
Calculation without verification
Outer wall consisting of a basic construction of stud with cavity insulation in the supporting structure. Sheathed interior side, , roomside single sheathed. Simple covering with cavity insulation. Compact facade.
Values of airborne sound insulation
Rw dB
C dB
Ctr dB

Graphic

Surface 2: Deckputz
Surface 1: Mineral flush, GUTEX adhesive and spachtelputz/reinforcement fabric, GUTEX
Cover leftside 1st layer: GUTEX Thermoflex
Bond: no composite action
Support: Finger-jointed solid wood width = 60mm
Cavity dampening: Cellulose insulation CLIMACELL
Bond: Rigid, execution of the prior art.
Sheathed rightside 1st layer: LivingBoard P5
Battens / profiles: Wood lath transversely b=60mm
Cavity dampening: Wood fiber facade insulation board ≥ 180kg/m³
Covering rightside1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Surface 2 Deckputz Fermacell, Knauf, Rigips 2 mm 2.7 kg/m2 - - - -
Surface 1 Mineral flush, GUTEX adhesive and spachtelputz/reinforcement fabric, GUTEX Gutex 5 mm 4.5 kg/m2 - - - -
Cover leftside 1st layer GUTEX Thermoflex Gutex 60 mm 3 kg/m2 - - 10.009 91.051
Bond no composite action - - - - - - -
Support Finger-jointed solid wood width = 60mm General Informations, Generic product, August Brühwiler, Dahinden Sägewerk, Filippi, Necker Holz, Schilliger Holz, Origin mark Swiss wood 160 mm 7.5 kg/m2 60 mm 625 mm 07.011 91.052
Cavity dampening Cellulose insulation CLIMACELL Catolet 160 mm 8.8 kg/m2 - - 10.010 91.046
Bond Rigid, execution of the prior art. - - - - - - -
Sheathed rightside 1st layer LivingBoard P5 Pfleiderer 15 mm 10.5 kg/m2 - - 07.015 91.145
Battens / profiles Wood lath transversely b=60mm Generic product, Origin mark Swiss wood 60 mm 2.8 kg/m2 60 mm 625 mm 07.011 91.052
Cavity dampening Wood fiber facade insulation board ≥ 180kg/m³ Gutex, Isover 60 mm 10.8 kg/m2 - - 10.009 91.051
Covering rightside1st layer Gypsum fiber or hard gypsum board ≥ 1000kg/m³ Fermacell, Knauf, Rigips 12.5 mm 13.3 kg/m2 - - 03.007 91.063

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Calculation Lignum/Kühn and Blickle 9 11 13 15 15 14 20 26 34 40 47 53 60 66 71 77 83 89 95 101 110 110

Airborne sound (R)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
48184.8
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
41361.3
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
6905.2
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
322.1
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
316.2
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
143.2
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
172.6
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
6.7
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
202.5
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
202.1
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
45.2
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
156.9
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.5
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
119.8
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
113.5
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
97.9
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
15.8
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
6.2
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
26.2
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
23
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
3.2
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
67.46666666666665
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
18.4
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)