Components

Construction assembly D0085

Lignum ID-№
D0085
Catalog number
D.1.01.M41
Source of construction assembly
Lignum, Year 2016
Base structure
Stud
Type of facade
Ventilated facade
Paneling
Without covering
Construction height
282 mm
Weight
52 kg/m2
U-value
≈ 0.201 W/m2K
GWP
22.50 kg CO2-eq/m2
Type sound insulation
Verified calculation
Outer wall consisting of a basic construction of stud with cavity insulation in the supporting structure with air flow resistivity [r] of 5≤ r ≤35 kPa s/m². Sheathed outside & interior, on the outside single sheathed, roomside single sheathed. Without covering. Ventilated facade.
Values of airborne sound insulation
Rw 45 dB
C -2 dB
Ctr -7 dB

Graphic

Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=50mm
Sheathed outside leftside 1st layer: Wood panel for structural purposes ≥ 600 kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface rightside: Glued joints/smoothed

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Cover leftside 1st layer Wood cladding horizontal, closed Generic product, VSH, Label swiss wood 22 mm 10.8 kg/m2 - - 07.009.01 91.052
Battens / profiles (ventilation) Wood lath transversely b=50mm Generic product, Label swiss wood 30 mm 1.2 kg/m2 50 mm 625 mm 07.011 91.052
Sheathed outside leftside 1st layer Wood panel for structural purposes ≥ 600 kg/m³ Swiss Krono, Pius Schuler, Stora Enso, Binderholz, Novatop, Pfleiderer 15 mm 9 kg/m2 - - 07.013 91.145
Bond Stiff, execution of the prior art. - - - - - - -
Support Rib/bar Generic product, Origin mark Swiss wood 200 mm 9.4 kg/m2 60 mm 625 mm 07.002 91.047
Cavity dampening Fiber insulation with 5≤ r ≤35 [kPa*s/m² Flumroc, Isover, Sager, Swisspor, Gutex, Isofloc, Schilliger Holz 200 mm 6.4 kg/m2 - - 10.008 91.173
Bond Stiff, execution of the prior art. - - - - - - -
Sheathed rightside 1st layer Gypsum fiber or hard gypsum board ≥ 1000kg/m³ Fermacell, Knauf, Rigips 15 mm 16 kg/m2 - - 03.007 91.063
Surface rightside Glued joints/smoothed Fermacell, Knauf, Rigips - - - - - -

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Calculation Lignum/Kühn and Blickle 13 16 18 21 24 26 28 28 30 33 36 39 41 43 44 44 44 53 62 69 78 87

Airborne sound (R)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
41363
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
37096
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
4214.8
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
320.7
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
315.6
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
158.9
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
156.3
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
5.1
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
220.5
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
220.1
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
69.5
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
150.6
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.3
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
99.9
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
95.1
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
89.6
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
5.6
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
4.8
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
22.5
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
20.2
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
2.3
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
50.96666666666667
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
13.9
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)