LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly D0265

Lignum ID-№
D0265
Catalog number
D.1.02.E14
Source of construction assembly
Lignum, Year 2016
Base structure
Stud
Type of facade
Ventilated facade and wall covering
Paneling
Substructure rigid screwed
Construction height
402 mm
Weight
68 kg/m2
U-value
≈ 0.135 W/m2K
GWP
36.00 kg CO2-eq/m2
Type sound insulation
Verified calculation
Outer wall consisting of a basic construction of stud with cavity insulation in the supporting structure with air flow resistivity [r] of 5≤ r ≤35 kPa s/m². Sheathed outside & interior, on the outside single sheathed, roomside single sheathed. Simple covering with cavity insulation. Ventilated facade.
Values of airborne sound insulation
Rw 48 dB
C -2 dB
Ctr -8 dB

Graphic

Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=50mm
Sheathed outside leftside 2nd layer: Wood fiber facade insulation board s' ≤ 50 [MN/m³]
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Battens / profiles: Wood lath transversely b=60mm
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Covering rightside1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface rightside: Glued joints/smoothed

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Cover leftside 1st layer Wood cladding horizontal, closed Generic product, VSH, Label swiss wood 22 mm 10.8 kg/m2 - - 07.009.01 91.052
Battens / profiles (ventilation) Wood lath transversely b=50mm Generic product, Label swiss wood 30 mm 1.2 kg/m2 50 mm 625 mm 07.011 91.052
Sheathed outside leftside 2nd layer Wood fiber facade insulation board s' ≤ 50 [MN/m³] Gutex, Isover 60 mm 10.8 kg/m2 - - 10.009 91.051
Bond Stiff, execution of the prior art. - - - - - - -
Support Rib/bar Generic product, Origin mark Swiss wood 200 mm 9.4 kg/m2 60 mm 625 mm 07.002 91.047
Cavity dampening Fiber insulation with 5≤ r ≤35 [kPa*s/m² Flumroc, Isover, Sager, Swisspor, Gutex, Isofloc, Schilliger Holz 200 mm 6.4 kg/m2 - - 10.008 91.173
Bond Stiff, execution of the prior art. - - - - - - -
Sheathed rightside 1st layer Gypsum fiber or hard gypsum board ≥ 1000kg/m³ Fermacell, Knauf, Rigips 15 mm 9 kg/m2 - - 03.007 91.063
Battens / profiles Wood lath transversely b=60mm Generic product, Origin mark Swiss wood 60 mm 2.8 kg/m2 60 mm 625 mm 07.011 91.052
Cavity dampening Fiber insulation with 5≤ r ≤35 [kPa*s/m² Flumroc, Isover, Sager, Swisspor, Gutex, Isofloc, Schilliger Holz 60 mm 1.9 kg/m2 - - 10.008 91.173
Covering rightside1st layer Gypsum fiber or hard gypsum board ≥ 1000kg/m³ Fermacell, Knauf, Rigips 15 mm 16 kg/m2 - - 03.007 91.063
Surface rightside Glued joints/smoothed Fermacell, Knauf, Rigips - - - - - -

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Calculation Lignum/Kühn and Blickle 12 14 16 18 18 18 23 29 36 43 50 56 63 69 74 80 86 92 98 104 110 110

Airborne sound (R)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
64876.2
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
57667.9
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
7234.5
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
403.9
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
396.8
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
214.7
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
181.8
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
7.8
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
244.5
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
243.9
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
68.7
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
175.2
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.5
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
159.8
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
152.5
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
146
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
6.5
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
7.3
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
36
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
32.9
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
3.1
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
60.86666666666667
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
16.6
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)