LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly C0104

Lignum ID-№
C0104
Catalog number
C.3.03.D11
Source of construction assembly
Lignum, Year 2016
Base structure
Solid wood panel
Sheathing
without sheathing
Paneling
Covering on one side
Reference fire protection
Lignum Dok. 4.1, Tabelle: 44X
Construction height
170 mm
Weight
62 kg/m2
U-value
≈ 0.235 W/m2K
GWP
20.30 kg CO2-eq/m2
Type sound insulation
Verified calculation
Partition wall single shellconsisting of a basic construction ofsolid timber without cavity insulation in the supporting structure. without sheathing. Covering on one side with cavity insulation.
Values of airborne sound insulation
Rw 50 dB
C -3 dB
C50-3150 -8 dB

Graphic

Support: Wood panel for structural purposes, Cross laminated timber, laminated timber ≥ 450 kg/m³
Bond: no composite action
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath transversely b=60mm
Cavity dampening: Fiber insulation with 5≤ r ≤50 [kPa * s/m]
Covering rightside1st layer: Plasterboard type A
Covering rightside 2nd layer: Plasterboard type A
Surface rightside: Smoothed joints

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Support Wood panel for structural purposes, Cross laminated timber, laminated timber ≥ 450 kg/m³ Willisauerstrasse 37, Pius Schuler, Stora Enso, Binderholz, Novatop, Pfleiderer, Kaufmann Oberholzer, Tschopp, Sidler Holz, Egg Holz Kälin, Schilliger Holz 80 mm 37.6 kg/m2 1000 mm 1000 mm 07.003.01 91.047
Bond no composite action - - - - - - -
Coupling Rubber mounted direct hanger b=60mm Ampack, Fermacell, Knauf, Rigips, Protektor 30 mm - - 834 mm - -
Battens / profiles Wood lath transversely b=60mm Generic product, Label swiss wood 30 mm 1.4 kg/m2 60 mm 625 mm 07.011 91.052
Cavity dampening Fiber insulation with 5≤ r ≤50 [kPa * s/m] Flumroc, Isover, Sager, Swisspor, Gutex, Isofloc, Schilliger Holz 60 mm 1.9 kg/m2 - - 10.008 91.173
Covering rightside1st layer Plasterboard type A Knauf, Rigips 15 mm 11 kg/m2 - - 03.008 91.064
Covering rightside 2nd layer Plasterboard type A Knauf, Rigips 15 mm 11 kg/m2 - - 03.008 91.064
Surface rightside Smoothed joints Knauf, Rigips - - - - 04.017 91.139

Ecological indicators according to the KBOB life cycle assessment data in the construction sector KBOB / ecobau / IPB 2009/1:2022, Version 6
(For the life cycle phases production and disposal, excluding the construction phase (Modules A4, A5) and the use phase (Module B), especially replacement (Module B4) or amortization periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
46731
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
41228
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
5501
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
487.30
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
480.10
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
209.20
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
270.80
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
7.10
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
395.20
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
394.60
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
127.20
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
267.50
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.40
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
92.00
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
85.30
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
82.30
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
3.20
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
6.70
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
20.30
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
17.30
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
2.90
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
0.00
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
23.80
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)