LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly C0465

Lignum ID-№
C0465
Catalog number
C.3.01.KROA2.1
Source of construction assembly
Prüfbericht 040204.V01, Year 2009
Base structure
Solid wood panel
Sheathing
without sheathing
Paneling
Without covering
Reference fire protection
Lignum Dok. 4.1, Tabelle: 44X
Construction height
100 mm
Weight
66 kg/m2
U-value
≈ 0.476 W/m2K
GWP
37.20 kg CO2-eq/m2
Type sound insulation
Measurement
Partition wall single shellconsisting of a basic construction ofsolid timber without cavity insulation in the supporting structure. without sheathing. Without covering.
Values of airborne sound insulation
Rw 36 dB
C -1 dB
C50-3150 -1 dB

Graphic

Support: SWISS KRONO MAGNUMBOARD OSB

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Support SWISS KRONO MAGNUMBOARD OSB Willisauerstrasse 37, Wittstocker Chaussee 1 100 mm 66 kg/m2 1000 mm 1000 mm 07.013 91.145

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement LSW Stephanskirchen bei Rosenheim 28 26 26 30 28 26 29 28 25 25 29 33 35 38 41 43 44 46 47 43 45
Calculation Lignum/Kühn and Blickle 22 25 27 30 33 35 37 36 33 36 33 35 38 40 41 41 41 50 59 66 75 84

Airborne sound (R)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
67980
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
60852
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
6996
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
726
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
719.4
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
345.2
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
371.6
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
6.9
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
545.2
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
544.5
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
208.6
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
335.9
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.4
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
178.9
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
172.3
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
137.3
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
35.3
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
6.4
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
37.2
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
31.9
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
5.3
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
0
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
29.3
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)