LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly C0466

Lignum ID-№
C0466
Catalog number
C.3.01.KROB1.1
Source of construction assembly
Kronoply GmbH, Year 2009
Base structure
Solid wood panel
Sheathing
Sheathed on one side
Paneling
Without covering
Reference fire protection
Lignum Dok. 4.1, Tabelle: 44X
Construction height
87 mm
Weight
64 kg/m2
U-value
≈ 0.508 W/m2K
GWP
36.10 kg CO2-eq/m2
Type sound insulation
Verified calculation
Partition wall single shellconsisting of a basic construction ofsolid timber without cavity insulation in the supporting structure. Sheathed on one side, leftside single sheathed. Without covering.
Values of airborne sound insulation
Rw 35 dB
C dB
C50-3150 dB

Graphic

Surface leftside: Smoothed joints
Sheathed leftside 1st layer: Rigidur H-Gipsfaserplatte
Bond: Stiff, execution of the prior art.
Support: SWISS KRONO MAGNUMBOARD OSB

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Surface leftside Smoothed joints Knauf, Rigips - - - - 04.017 91.139
Sheathed leftside 1st layer Rigidur H-Gipsfaserplatte Rigips 12.5 mm 15 kg/m2 - - 03.007 91.063
Bond Stiff, execution of the prior art. - - - - - - -
Support SWISS KRONO MAGNUMBOARD OSB Willisauerstrasse 37, Wittstocker Chaussee 1 75 mm 49.5 kg/m2 1000 mm 1000 mm 07.013 91.145

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Calculation Lignum/Kühn and Blickle 19 22 24 27 30 32 34 34 30 33 30 33 35 37 38 38 38 47 56 63 72 81

Airborne sound (R)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
64080
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
57654
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
6319.5
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
583.1
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
576.9
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
296.2
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
278.7
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
6.4
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
410.3
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
409.8
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
157.8
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
252
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.4
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
171.2
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
165
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
138.8
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
26.5
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
6
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
36.1
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
31.9
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
4.2
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
0
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
22.7
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)