LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly C0494

Lignum ID-№
C0494
Catalog number
C.3.01.21001299/W02
Source of construction assembly
21001299/W02, Year 2021
Base structure
Solid wood panel
Sheathing
Sheathed on one side
Paneling
Without covering
Reference fire protection
Lignum Dok. 4.1, Tabelle: 44X
Construction height
127 mm
Weight
94 kg/m2
U-value
≈ 0.446 W/m2K
GWP
40.50 kg CO2-eq/m2
Type sound insulation
Measurement
Partition wall single shellconsisting of a basic construction ofsolid timber without cavity insulation in the supporting structure. Sheathed on one side, leftside double sheathed. Without covering.
Values of airborne sound insulation
Rw 44 dB
C -1 dB
C50-3150 -1 dB

Graphic

Sheathed leftside 2nd layer: GKF/DF Knauf Piano
Sheathed leftside 1st layer: Phone Star TRI
Bond: Stiff, execution of the prior art.
Support: SWISS KRONO MAGNUMBOARD OSB

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Sheathed leftside 2nd layer GKF/DF Knauf Piano Knauf 12.5 mm 10 kg/m2 - - 03.008 91.064
Sheathed leftside 1st layer Phone Star TRI Wolf Bavaria 15 mm 18 kg/m2 - - 03.013 91.062
Bond Stiff, execution of the prior art. - - - - - - -
Support SWISS KRONO MAGNUMBOARD OSB Willisauerstrasse 37, Wittstocker Chaussee 1 100 mm 66 kg/m2 1000 mm 1000 mm 07.013 91.145

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement Ift Rosenheim 34 26 34 37 36 33 34 33 35 33 36 41 45 48 52 56 59 58 61 62 63
Calculation Lignum/Kühn and Blickle 23 26 29 31 34 37 38 38 34 37 34 37 39 42 42 42 43 51 60 67 76 85

Airborne sound (R)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
74279.19999999998
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
65717.6
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
8436.6
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
741.5
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
733.1
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
358.9
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
371.6
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
8.699999999999998
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
546.1
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
545.4
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
209.4
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
335.9
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.5
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
193.4
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
185
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
150.1
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
35.3
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
8.199999999999998
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
40.5
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
34.8
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
5.7
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
0
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
29.5
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)