LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly A2254

Lignum ID-№
A2254
Catalog number
A.3.04.DE700F
Source of construction assembly
Tschopp, Year 2017
Base structure
BRESTA Solid Timber System
Paneling
Substructure rigid screwed
Reference fire protection
Lignum Dok. 4.1 / Tabelle: 434 Gilt nicht für Bauteile mit Beschwerung im Hohlraum.
Construction height
258 mm
Weight
137 kg/m2
U-value
≈ 0.338 W/m2K
GWP
26.20 kg CO2-eq/m2
Type sound insulation
Calculation
Ceiling consisting of a basic construction of BRESTA Solid Timber System, without sheathing, simple ceiling covering. stiff screwed substructure, with dampening in supporting structure, without cavity insulation in the supporting structure. With dampening on the supporting structure, without impact sound insulation and without screed.
Values of airborne sound insulation
Rw 39 dB
C -1 dB
C50-3150 -5 dB
Values of footfall sound insulation
Ln,w 76 dB
CI -3 dB
CI50-2500 -3 dB

Graphic

Flooring: Laminate
Dampening on Supporting structure: Gypsum fiber board ≥ 1000kg/m³
Bond: no composite action
Supporting structure: Bresta Solid timber panel
Dampening in supporting structure: Gypsum fiber board ≥ 1000kg/m³
Bond: Stiff, execution of the prior art.
Battens / profiles: Wood lath b=60mm
Ceiling covering 1st layer: Plasterboard type A
Surface / treatment: Innenputz, verspachtelt

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Flooring Laminate Generic product 15 mm 15 kg/m2 - - 11.013 91.011
Dampening on Supporting structure Gypsum fiber board ≥ 1000kg/m³ Fermacell, Knauf, Rigips 18 mm 19.2 kg/m2 - - 03.007 91.063
Bond no composite action - - - - - - -
Supporting structure Bresta Solid timber panel Tschopp 180 mm 88.2 kg/m2 1000 mm 1000 mm 07.011.02 91.052
Dampening in supporting structure Gypsum fiber board ≥ 1000kg/m³ Fermacell, Knauf, Rigips 18 mm - - - 03.007 91.063
Bond Stiff, execution of the prior art. - - - - - - -
Battens / profiles Wood lath b=60mm Generic product, Origin mark Swiss wood 30 mm 2.2 kg/m2 60 mm 400 mm 07.011 91.052
Ceiling covering 1st layer Plasterboard type A Knauf, Rigips 12.5 mm 9.2 kg/m2 - - 03.008 91.064
Surface / treatment Innenputz, verspachtelt Fermacell, Knauf, Rigips 3 mm 4.2 kg/m2 - - 04.001 91.139

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Calculation Lignum/Kühn and Blickle 28 30 32 34 34 33 39 44 52 59 66 72 79 85 90 96 102 108 110 110 110 110
Impact sound (Ln) Calculation Lignum/Kühn and Blickle 53 54 55 56 59 63 60 57 53 49 45 42 38 35 33 30 27 24 21 18 13 8

Airborne sound (R)

Loading...

Impact sound (Ln)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
61774.4
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
53859.1
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
7905.7
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
998.5
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
986.9
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
508
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
483.4
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
11.1
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
896.8
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
895.8
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
412.4
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
483.4
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.7
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
105.8
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
95.3
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
95.3
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
0
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
10.5
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
26.2
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
22.1
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
4.1
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
153.26666666666665
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
41.8
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)