LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly A2709

Lignum ID-№
A2709
Catalog number
A.3.01.21001299/D01
Source of construction assembly
Swiss Krono, Year 2021
Base structure
Solid timber, derived wood products
Paneling
Without covering
Reference fire protection
Lignum Dok. 4.1 / Tabelle: 43X
Construction height
185 mm
Weight
117 kg/m2
U-value
≈ 0.342 W/m2K
GWP
68.40 kg CO2-eq/m2
Type sound insulation
Measurement
Ceiling consisting of a basic construction of solid timber, derived wood product, without sheathing, without ceiling covering, without dampening in the supporting structure, without cavity insulation in the supporting structure. Without dampening on the supporting structure, with impact sound insulation with a dynamic stiffness [s'] of 120 MN/m³ and without screed.
Values of airborne sound insulation
Rw 43 dB
C -1 dB
C50-3150 -1 dB
Values of footfall sound insulation
Ln,w 82 dB
CI -5 dB
CI50-2500 -5 dB

Graphic

Impact sound insulation: Wood fiber generic product
Sub-floor: Trickling protection
Bond: no composite action
Supporting structure: SWISS KRONO MAGNUMBOARD OSB

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Impact sound insulation Wood fiber generic product Generic product 10 mm 1.6 kg/m2 - - 10.009 91.051
Sub-floor Trickling protection Generic product 0.5 mm 0.4 kg/m2 - - 09.007 91.037
Bond no composite action - - - - - - -
Supporting structure SWISS KRONO MAGNUMBOARD OSB Willisauerstrasse 37, Wittstocker Chaussee 1 175 mm 115.5 kg/m2 1000 mm 1000 mm 07.013 91.145

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement Ift Rosenheim 24 35 30 34 38 37 36 36 33 34 37 39 42 44 45 47 45 46 48 48 49
Calculation Lignum/Kühn and Blickle 25 27 30 33 35 38 40 39 36 39 35 38 41 43 44 45 44 50 59 67 76 85
Impact sound (Ln) Measurement Ift Rosenheim 63 62 64 65 68 76 78 78 82 83 83 84 83 83 81 77 71 67 64 61 56
Calculation Lignum/Kühn and Blickle 56 57 57 57 58 58 59 63 69 69 75 76 76 77 79 81 85 82 76 71 65 59

Airborne sound (R)

Loading...

Impact sound (Ln)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
124092.5
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
110095.7
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
13777
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
1298
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
1286.2
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
617.2
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
664.3
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
12.4
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
965.8
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
964.6
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
368.4
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
596.2
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.7
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
328.8
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
316.9
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
250
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
67.6
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
11.6
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
68.4
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
57.9
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
10.5
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
190.66666666666666
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
52
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)