Components

Construction assembly A0030

Lignum ID-№
A0030
Catalog number
A.2.03.4311
Source of construction assembly
Lignatur_11_LFE_50kg_Nassaufbau_68db_60db, Year 2009
Base structure
Hollow box element
Paneling
Without covering
Reference fire protection
VKF Brandschutzanwendung Nr. 15421
Construction height
277 mm
Weight
197 kg/m2
U-value
≈ 0.357 W/m2K
GWP
0.00 kg CO2-eq/m2
Type sound insulation
Measurement
Ceiling consisting of a basic construction of hollow box element, without sheathing, without ceiling covering, with dampening in supporting structure, without cavity insulation in the supporting structure. Without dampening on the supporting structure, with impact sound insulation with a dynamic stiffness [s'] of 6.3 MN/m³ and with cement screed.
Values of airborne sound insulation
Rw 68 dB
C -2 dB
C50-3150 -6 dB
Values of footfall sound insulation
Ln,w 60 dB
CI -8 dB
CI50-2500 -5 dB

Graphic

On-lying material: Cement screed
Impact sound insulation: ISOVER PS 81 D = 30/27mm
Sub-floor: Lignatur surface element sheathing above
Supporting structure: Lignatur surface element LFE
Dampening in supporting structure: Dampening gravel ≤ 1400 kg/m³
Lower skin layer 1: Lignatur surface element sheathing below

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
On-lying material Cement screed Generic product 50 mm 110 kg/m2 - - 04.006 91.136
Impact sound insulation ISOVER PS 81 D = 30/27mm Isover 27 mm 2.2 kg/m2 - - 10.001.01 91.173
Sub-floor Lignatur surface element sheathing above Lignatur 31 mm 14.6 kg/m2 - - 07.011.01 91.052
Supporting structure Lignatur surface element LFE Lignatur 138 mm 1.1 kg/m2 31 mm 242 mm 07.011.01 91.052
Dampening in supporting structure Dampening gravel ≤ 1400 kg/m³ Fermacell, Zisola 45 mm 54.9 kg/m2 - - 03.011 91.062
Lower skin layer 1 Lignatur surface element sheathing below Lignatur 31 mm 14.6 kg/m2 - - 07.011.01 91.052

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement Lignatur Berechnung 30 31 41 49 55 56 62 63 61 57 58 62 69 73 74 75 76 75 75 79 78
Calculation Lignum/Kühn and Blickle 13 16 18 21 24 26 28 27 30 33 36 38 41 43 44 43 44 53 61 69 78 86
Impact sound (Ln) Measurement Lignatur Berechnung 61 61 60 57 54 51 49 52 54 58 58 57 54 52 54 56 53 52 51 45 42
Calculation Lignum/Kühn and Blickle 68 68 69 69 69 70 71 75 75 75 75 76 76 77 79 83 85 79 74 70 63 58

Airborne sound (R)

Loading...

Impact sound (Ln)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
0
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
0
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
0
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
0
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
0
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
0
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
0
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
0
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
0
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
0
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
0
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
0
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
0
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
0
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
0
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
0
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
0
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
0
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
0
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
0
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
0
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
0
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)