LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly B0327

Lignum ID-№
B0327
Catalog number
B.3.03.KRO E3.1
Source of construction assembly
Kronoply , Year 2009
Base structure
Solid wood panel
Sheathing
Sheathed on one side
Reference fire protection
Lignum Dok. 4.1 / Tabelle: 44X
Construction height
475 mm
Weight
226 kg/m2
U-value
≈ 0.177 W/m2K
GWP
113.50 kg CO2-eq/m2
Type sound insulation
Verified calculation
Partition wall double shell consisting of a basic construction of solid timber without cavity insulation in the supporting structure. Sheathed in the interspace.Double covering. With cavity insulation between the wall panels.
Values of airborne sound insulation
Rw 72 dB
C dB
C50-3150 dB

Graphic

Surface leftside: Smoothed joints
Cover leftside 2nd layer: Rigidur H-Gipsfaserplatte
Cover leftside 1st layer: Rigidur H-Gipsfaserplatte
Battens / profiles: MW-upright profile b=50mm
Coupling: Air
Bond: Stiff, execution of the prior art.
Support leftside: SWISS KRONO MAGNUMBOARD OSB
Bond: Stiff, execution of the prior art.
Sheathed outside leftside 1st layer: Rigidur H-Gipsfaserplatte
Sheathed outside leftside 2nd layer: Rigidur H-Gipsfaserplatte
Intermediate insulation: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Air gap: Air
Sheathed far rightside 2nd layer: Rigidur H-Gipsfaserplatte
Sheathed outside rightside 1st layer: Rigidur H-Gipsfaserplatte
Bond: Stiff, execution of the prior art.
Support rightside: SWISS KRONO MAGNUMBOARD OSB
Bond: Stiff, execution of the prior art.

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Surface leftside Smoothed joints Knauf, Rigips - - - - 04.017 91.139
Cover leftside 2nd layer Rigidur H-Gipsfaserplatte Rigips 12.5 mm 15 kg/m2 - - 03.007 91.063
Cover leftside 1st layer Rigidur H-Gipsfaserplatte Rigips 12.5 mm 15 kg/m2 - - 03.007 91.063
Battens / profiles MW-upright profile b=50mm Fermacell, Knauf, Rigips, Protektor 50 mm 1.1 kg/m2 - 625 mm 06.011 91.143
Coupling Air - 10 mm - - - - -
Bond Stiff, execution of the prior art. - - - - - - -
Support leftside SWISS KRONO MAGNUMBOARD OSB Willisauerstrasse 37, Wittstocker Chaussee 1 100 mm 66 kg/m2 1000 mm 1000 mm 07.013 91.145
Bond Stiff, execution of the prior art. - - - - - - -
Sheathed outside leftside 1st layer Rigidur H-Gipsfaserplatte Rigips 12.5 mm 15 kg/m2 - - 03.007 91.063
Sheathed outside leftside 2nd layer Rigidur H-Gipsfaserplatte Rigips 12.5 mm 15 kg/m2 - - 03.007 91.063
Intermediate insulation Fiber insulation with 5≤ r ≤35 [kPa*s/m² Flumroc, Isover, Sager, Swisspor, Gutex, Isofloc, Schilliger Holz 120 mm 3.8 kg/m2 - - 10.008 91.173
Air gap Air - 20 mm - - - - -
Sheathed far rightside 2nd layer Rigidur H-Gipsfaserplatte Rigips 12.5 mm 15 kg/m2 - - 03.007 91.063
Sheathed outside rightside 1st layer Rigidur H-Gipsfaserplatte Rigips 12.5 mm 15 kg/m2 - - 03.007 91.063
Bond Stiff, execution of the prior art. - - - - - - -
Support rightside SWISS KRONO MAGNUMBOARD OSB Willisauerstrasse 37, Wittstocker Chaussee 1 100 mm 66 kg/m2 1000 mm 1000 mm 07.013 91.145
Bond Stiff, execution of the prior art. - - - - - - -

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Calculation Lignum/Kühn and Blickle 23 23 23 28 37 44 50 53 54 60 60 66 73 79 84 90 96 102 108 110 110 110

Airborne sound (R)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
208958.5
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
190382.5
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
18297.1
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
1629.3
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
1611.3
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
862.8
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
743.2
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
18.7
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
1098.1
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
1096.5
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
424.7
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
671.8
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
1
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
527.1
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
509.1
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
439.1
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
70.6
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
17.6
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
113.5
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
101.8
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
11.6
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
0
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
61.4
kg C/m2
B1-B7