LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly F0138

Lignum ID-№
F0138
Catalog number
F.2.01.FH1
Source of construction assembly
GAS 01-F01-04-de-01, Year 2019
Base structure
Hollow box element
Sheathing
Sheathed left & rightside
Paneling
Without covering
Reference fire protection
VKF Brandschutzanwendung Nr. 15421
Construction height
610 mm
Weight
337 kg/m2
U-value
≈ 0.180 W/m2K
GWP
0.00 kg CO2-eq/m2
Type sound insulation
Verified calculation
Flat roof / shed roof consisting of a basic construction of hollow box element without cavity insulation in the supporting structure. Sheathed left & rightside, leftside double sheathed rightside single sheathed. Without covering with insulation on top of the sub-floor.
Values of airborne sound insulation
Rw 62 dB
C dB
Ctr dB
Values of footfall sound insulation
Ln,w dB
CI dB
CI50-2500 dB

Graphic

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Calculation Lignum/Kühn and Blickle 14 16 18 20 21 20 22 28 36 43 50 57 63 69 75 81 86 92 98 104 110 110
Impact sound (Ln) Calculation Lignum/Kühn and Blickle 67 68 69 70 72 76 77 74 69 65 61 57 54 51 48 46 43 40 37 34 29 24

Airborne sound (R)

Loading...

Ecological indicators according to the KBOB life cycle assessment data in the construction sector KBOB / ecobau / IPB 2009/1:2022, Version 6
(For the life cycle phases production and disposal, excluding the construction phase (Modules A4, A5) and the use phase (Module B), especially replacement (Module B4) or amortization periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
230720
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
187913
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
43259
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
1695.30
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
1665.90
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
712.20
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
953.00
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
31.80
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
1226.20
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
1224.10
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
356.50
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
867.00
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
1.90
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
470.80
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
440.90
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
355.10
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
86.00
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
29.90
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
120.90
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
93.30
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
27.70
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
275.37
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
75.10
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)