LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly A2084

Lignum ID-№
A2084
Catalog number
A.3.01.DE160I
Source of construction assembly
Tschopp, Year 2017
Base structure
BRESTA Solid Timber System
Paneling
Without covering
Reference fire protection
Lignum Dok. 4.1 / Tabelle: 434
Construction height
495 mm
Weight
478 kg/m2
U-value
≈ 0.222 W/m2K
GWP
46.00 kg CO2-eq/m2
Type sound insulation
Calculation
Ceiling consisting of a basic construction of BRESTA Solid Timber System, without sheathing, without ceiling covering, without dampening in the supporting structure, without cavity insulation in the supporting structure. With dampening on the supporting structure, with impact sound insulation with a dynamic stiffness [s'] of 60 MN/m³ and with cement screed.
Values of airborne sound insulation
Rw 72 dB
C -3 dB
C50-3150 0 dB
Values of footfall sound insulation
Ln,w 43 dB
CI 0 dB
CI50-2500 5 dB

Graphic

Flooring: Fllor
On-lying material: Cement screed
Impact sound insulation: Wood fiber generic product
Additional insulation: Glass wool 20mm with dynamic stiffness s' of ≤ 13.5 [MN/m³]
Dampening on Supporting structure: Filling 1376 kg/m³
Sub-floor: Trickling protection
Bond: no composite action
Supporting structure: Bresta Solid timber panel

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Flooring Fllor Generic product 15 mm 15 kg/m2 - - 11.013 91.011
On-lying material Cement screed Generic product 80 mm 176 kg/m2 - - 04.006 91.136
Impact sound insulation Wood fiber generic product Generic product 20 mm 3.2 kg/m2 - - 10.009 91.051
Additional insulation Glass wool 20mm with dynamic stiffness s' of ≤ 13.5 [MN/m³] Isover, Sager, Swisspor, Zisola 20 mm 1.6 kg/m2 - - 10.001.01 91.173
Dampening on Supporting structure Filling 1376 kg/m³ Generic product 120 mm 165.1 kg/m2 - - 03.011 91.062
Sub-floor Trickling protection Generic product 0.5 mm 0.4 kg/m2 - - 09.007 91.037
Bond no composite action - - - - - - -
Supporting structure Bresta Solid timber panel Tschopp 240 mm 117.6 kg/m2 1000 mm 1000 mm 07.011.02 91.052

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Calculation Lignum/Kühn and Blickle 36 39 41 44 47 49 51 51 53 56 59 62 64 67 68 68 67 73 83 90 99 108
Impact sound (Ln) Calculation Lignum/Kühn and Blickle 45 45 46 46 46 47 48 51 52 52 52 52 53 53 55 58 62 59 53 48 41 36

Airborne sound (R)

Loading...

Impact sound (Ln)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
108056.3
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
84364.3
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
23608.6
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
1342.3
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
1311.2
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
664.4
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
652.5
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
30.7
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
1208.4
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
1206.4
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
560.6
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
645.9
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
1.5
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
139.4
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
110.5
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
103.8
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
6.6
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
29.2
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
46
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
35.6
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
10.4
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
199.46666666666667
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
54.4
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)