LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly C0086

Lignum ID-№
C0086
Catalog number
C.1.01.O0
Source of construction assembly
Lignum, Year 2016
Base structure
Stud
Sheathing
Sheathed on both sides
Paneling
Without covering
Reference fire protection
Lignum Dok. 4.1, Tabelle: 442
Construction height
200 mm
Weight
51 kg/m2
U-value
≈ 0.242 W/m2K
GWP
19.20 kg CO2-eq/m2
Type sound insulation
Verified calculation
Partition wall single shellconsisting of a basic construction ofstud with cavity insulation in the supporting structure with air flow resistivity [r] of 5≤ r ≤35 kPa s/m². Sheathed on both sides, leftside double sheathed, rightside double sheathed. Without covering.
Values of airborne sound insulation
Rw 45 dB
C -1 dB
C50-3150 -2 dB

Graphic

Surface leftside: Smoothed joints
Sheathed leftside 2nd layer: Plasterboard type A
Sheathed leftside 1st layer: Wood panel for structural purposes ≥ 600 kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Wood panel for structural purposes ≥ 600 kg/m³
Sheathed rightside 2nd layer: Plasterboard type A
Surface rightside: Smoothed joints

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Surface leftside Smoothed joints Knauf, Rigips - - - - 04.017 91.139
Sheathed leftside 2nd layer Plasterboard type A Knauf, Rigips 15 mm 11 kg/m2 - - 03.008 91.064
Sheathed leftside 1st layer Wood panel for structural purposes ≥ 600 kg/m³ Swiss Krono, Pius Schuler, Stora Enso, Binderholz, Novatop, Pfleiderer 15 mm 9 kg/m2 - - 07.013 91.145
Bond Stiff, execution of the prior art. - - - - - - -
Support Rib/bar Generic product, Origin mark Swiss wood 140 mm 6.6 kg/m2 60 mm 625 mm 07.002 91.047
Cavity dampening Fiber insulation with 5≤ r ≤35 [kPa*s/m² Flumroc, Isover, Sager, Swisspor, Gutex, Isofloc, Schilliger Holz 140 mm 4.5 kg/m2 - - 10.008 91.173
Bond Stiff, execution of the prior art. - - - - - - -
Sheathed rightside 1st layer Wood panel for structural purposes ≥ 600 kg/m³ Swiss Krono, Pius Schuler, Stora Enso, Binderholz, Novatop, Pfleiderer 15 mm 9 kg/m2 - - 07.013 91.145
Sheathed rightside 2nd layer Plasterboard type A Knauf, Rigips 15 mm 11 kg/m2 - - 03.008 91.064
Surface rightside Smoothed joints Knauf, Rigips - - - - 04.017 91.139

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Calculation Lignum/Kühn and Blickle 11 13 16 19 21 24 26 25 28 31 34 37 40 43 45 47 50 53 55 58 64 69

Airborne sound (R)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
35800.2
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
31694.4
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
4080.2
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
294.4
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
290.1
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
153.8
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
135.5
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
4.4
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
204.9
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
204.6
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
79.4
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
125.2
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.3
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
89
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
84.7
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
74.59999999999998
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
10.2
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
4.2
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
19.2
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
17
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
2.2
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
0
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
11.3
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)