Construction assembly C0358

Lignum ID-№
C0358
Catalog number
C.3.01.IW120D
Source of construction assembly
Tschopp, Year 2017
Base structure
BRESTA Solid Timber System
Sheathing
Sheathed on one side
Paneling
Without covering
Reference fire protection
Lignum Dok. 4.1, Tabelle: 444
Construction height
168 mm
Weight
120 kg/m2
U-value
≈ 0.412 W/m2K
GWP
9.80 kg CO2-eq/m2
Type sound insulation
Calculation
Partition wall single shellconsisting of a basic construction ofBRESTA Solid Timber System without cavity insulation in the supporting structure. Sheathed on one side, rightside single sheathed. Without covering.
Values of airborne sound insulation
Rw 60 dB
C -4 dB
C50-3150 dB

Graphic

Support: Bresta Solid timber panel
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Clay panels
Surface rightside: Innenputz, verspachtelt

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Support Bresta Solid timber panel Tschopp 140 mm 68.6 kg/m2 1000 mm 1000 mm 07.011.02 91.052
Bond Stiff, execution of the prior art. - - - - - - -
Sheathed rightside 1st layer Clay panels Generic product 25 mm 47.5 kg/m2 - - - -
Surface rightside Innenputz, verspachtelt Fermacell, Knauf, Rigips 3 mm 4.2 kg/m2 - - 04.001 91.139

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Calculation Lignum/Kühn and Blickle 26 28 30 33 35 37 37 34 35 44 53 60 67 74 79 85 91 97 103 109 110 110

Airborne sound (R)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
30510.2
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
26012
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
4493.4
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
716.6
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
709.5
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
345.9
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
367
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
6.7
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
684.9
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
684.2
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
317.2
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
367
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.4
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
34.9
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
28.6
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
28.6
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
0
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
6.3
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
9.8
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
7.1
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
2.7
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
0
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
30.9
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)