LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly D1197

Lignum ID-№
D1197
Catalog number
D.3.04.21001299/W07
Source of construction assembly
21-001299-PRO1 PB W07-F02-04-de-01, Year 2021
Base structure
Solid timber, derived wood products
Type of facade
Compact facade and wall covering
Paneling
Air
Construction height
325 mm
Weight
98 kg/m2
U-value
≈ 0.107 W/m2K
GWP
59.80 kg CO2-eq/m2
Type sound insulation
Measurement
Outer wall consisting of a basic construction of solid timber, derived wood product without cavity insulation in the supporting structure. Sheathed outer side, on the outside single sheathed. Double covering with cavity insulation. Compact facade.
Values of airborne sound insulation
Rw 65 dB
C -2 dB
Ctr -9 dB

Graphic

Sheathed outside leftside 1st layer: Rockwool ≥ 60kg/m³
Bond: Stiff, execution of the prior art.
Support: SWISS KRONO MAGNUMBOARD OSB
Coupling: Air
Battens / profiles: CD-ceiling profile b=60mm
Cavity dampening: Mineral Plus KP 034
Covering rightside1st layer: GKF/DF Knauf Piano
Covering rightside 2nd layer: GKF/DF Knauf Piano

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Sheathed outside leftside 1st layer Rockwool ≥ 60kg/m³ Generic product 140 mm 10.5 kg/m2 - - 10.008 91.173
Bond Stiff, execution of the prior art. - - - - - - -
Support SWISS KRONO MAGNUMBOARD OSB Willisauerstrasse 37, Wittstocker Chaussee 1 100 mm 66 kg/m2 1000 mm 1000 mm 07.013 91.145
Coupling Air - 10 mm - - - - -
Battens / profiles CD-ceiling profile b=60mm Fermacell, Knauf, Rigips, Protektor 50 mm 1.6 kg/m2 60 mm 625 mm 06.011 91.143
Cavity dampening Mineral Plus KP 034 Knauf Insulation 40 mm 0.9 kg/m2 - - 10.001 91.173
Covering rightside1st layer GKF/DF Knauf Piano Knauf 12.5 mm 10 kg/m2 - - 03.008 91.064
Covering rightside 2nd layer GKF/DF Knauf Piano Knauf 12.5 mm 10 kg/m2 - - 03.008 91.064

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement Ift Rosenheim 23 24 30 38 45 48 53 54 57 57 62 67 73 78 85 88 88 88 86 84 76
Calculation Lignum/Kühn and Blickle 22 24 26 27 26 29 37 42 43 50 50 56 63 69 74 80 86 92 98 104 110 110

Airborne sound (R)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
118461.4
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
108565.9
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
9757.9
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
838.9
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
829
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
454.8
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
371.6
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
10.2
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
568.4
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
567.5
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
231.6
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
335.9
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.6
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
268.5
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
258.9
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
223.9
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
35.3
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
9.5
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
59.8
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
53.4
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
6.3
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
108.9
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
29.7
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)