LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly A0094

Lignum ID-№
A0094
Catalog number
A.1.01.A50
Source of construction assembly
Lignum, Year 2016
Base structure
Ribs / joists
Paneling
Without covering
Reference fire protection
Lignum Dok. 4.1 / Tabelle: 431-1
Construction height
352 mm
Weight
75 kg/m2
U-value
≈ 0.428 W/m2K
GWP
31.90 kg CO2-eq/m2
Type sound insulation
Verified calculation
Ceiling consisting of a basic construction of ribs / joists, without sheathing, without ceiling covering, without dampening in the supporting structure, without cavity insulation in the supporting structure. Without dampening on the supporting structure, with impact sound insulation with a dynamic stiffness [s'] of 30 MN/m³ and with dry screed.
Values of airborne sound insulation
Rw 42 dB
C -1 dB
C50-3150 -1 dB
Values of footfall sound insulation
Ln,w 73 dB
CI 0 dB
CI50-2500 0 dB

Graphic

On-lying material: Floor heating system Therm38 longitudinal grooves
Impact sound insulation: Wood fiber with dynamic stiffness s' of ≤ 30 [MN / m²]
Sub-floor: Wood panel for structural purposes ≥ 450 kg/m³
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
On-lying material Floor heating system Therm38 longitudinal grooves Fermacell, Knauf, Rigips 23 mm 28.3 kg/m2 - - 03.007 91.063
Impact sound insulation Wood fiber with dynamic stiffness s' of ≤ 30 [MN / m²] Gutex, Isover 22 mm 3.5 kg/m2 - - 10.009 91.051
Sub-floor Wood panel for structural purposes ≥ 450 kg/m³ Swiss Krono, Pius Schuler, Stora Enso, Binderholz, Novatop, Pfleiderer 27 mm 12.7 kg/m2 - - 07.001 91.048
Bond Stiff, execution of the prior art. - - - - - - -
Supporting structure Rib/bar Generic product, Label swiss wood 280 mm 30.7 kg/m2 140 mm 625 mm 07.003.01 91.047

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement Lignum Berechnung 17 20 22 24 23 25 27 28 33 40 46 50 55 60 65 70 75 82 70
Calculation Lignum/Kühn and Blickle 17 20 22 25 28 30 32 32 34 37 40 43 45 47 48 48 48 57 66 73 82 91
Impact sound (Ln) Measurement Lignum Berechnung 71 72 73 74 78 79 80 82 79 76 73 71 69 68 66 64 62 58 54
Calculation Lignum/Kühn and Blickle 64 64 65 65 65 66 67 70 71 71 71 71 72 73 75 78 81 75 69 65 59 53

Airborne sound (R)

Loading...

Impact sound (Ln)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
63371.1
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
57295.8
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
6108.9
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
588.1
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
581.2
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
335.5
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
246.7
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
7.1
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
442.7
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
442.3
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
203.9
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
237.8
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.4
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
146.5
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
139.8
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
131.1
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
8.699999999999998
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
6.7
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
31.9
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
28.8
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
3.1
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
80.66666666666667
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
22
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)