LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly A2219

Lignum ID-№
A2219
Catalog number
A.3.01.DE455D
Source of construction assembly
Tschopp, Year 2017
Base structure
BRESTA Solid Timber System
Paneling
Without covering
Reference fire protection
Lignum Dok. 4.1 / Tabelle: 434
Construction height
525 mm
Weight
631 kg/m2
U-value
≈ 0.225 W/m2K
GWP
72.10 kg CO2-eq/m2
Type sound insulation
Calculation
Ceiling consisting of a basic construction of BRESTA Solid Timber System, without sheathing, without ceiling covering, without dampening in the supporting structure, without cavity insulation in the supporting structure. With dampening on the supporting structure, with impact sound insulation with a dynamic stiffness [s'] of 40 MN/m³ and with cement screed.
Values of airborne sound insulation
Rw 73 dB
C -2 dB
C50-3150 0 dB
Values of footfall sound insulation
Ln,w 41 dB
CI -7 dB
CI50-2500 1 dB

Graphic

Flooring: Fllor
On-lying material: Cement screed
Impact sound insulation: Wood fiber generic product
Dampening on Supporting structure: Cement screed with EPS
Sub-floor: Construction concrete, CEM II / A (cement content 290 kg/m³)
Bond: Rigid, execution of the prior art.
Supporting structure: Bresta Solid timber panel

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Flooring Fllor Generic product 15 mm 15 kg/m2 - - 11.013 91.011
On-lying material Cement screed Generic product 80 mm 176 kg/m2 - - 04.006 91.136
Impact sound insulation Wood fiber generic product Generic product 30 mm 4.8 kg/m2 - - 10.009 91.051
Dampening on Supporting structure Cement screed with EPS Generic product 120 mm 54 kg/m2 - - 04.006 91.136
Sub-floor Construction concrete, CEM II / A (cement content 290 kg/m³) Generic product 130 mm 308.1 kg/m2 - - 01.002 91.061
Bond Rigid, execution of the prior art. - - - - - - -
Supporting structure Bresta Solid timber panel Tschopp 150 mm 73.5 kg/m2 1000 mm 1000 mm 07.011.02 91.052

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Calculation Lignum/Kühn and Blickle 36 39 41 44 47 49 51 51 53 56 59 61 64 66 67 67 67 76 84 91 100 107
Impact sound (Ln) Calculation Lignum/Kühn and Blickle 45 45 46 46 46 47 48 51 52 52 52 52 53 54 56 60 62 56 51 47 41 37

Airborne sound (R)

Loading...

Impact sound (Ln)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
133081.3
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
106710.8
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
26343.8
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
935.7
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
898.5
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
481.3
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
420.7
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
36.8
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
781
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
779.1
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
360.9
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
418.2
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
1.6
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
158.2
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
123
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
120.5
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
2.5
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
35.2
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
72.09999999999998
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
62
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
10.1
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
129.4333333333333
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
35.3
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)