Components

Construction assembly D1189

Lignum ID-№
D1189
Catalog number
D.1.04.SKV06
Source of construction assembly
Swiss Krono, Year 2020
Base structure
Stud
Type of facade
Compact facade and wall covering
Paneling
Substructure rigid screwed
Construction height
315 mm
Weight
64 kg/m2
U-value
≈ 0.130 W/m2K
GWP
38.20 kg CO2-eq/m2
Type sound insulation
Measurement
Outer wall consisting of a basic construction of stud with cavity insulation in the supporting structure. Sheathed outside & interior, on the outside single sheathed, roomside single sheathed. Simple covering with cavity insulation. Compact facade.
Values of airborne sound insulation
Rw 54 dB
C -2 dB
Ctr -7 dB

Graphic

Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Sheathed outside leftside 2nd layer: Isolair
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Isocell
Bond: Rigid, execution of the prior art.
Sheathed rightside 1st layer: SWISS KRONO OSB/3
Battens / profiles: Wood lath transversely b=60mm
Cavity dampening: PAVAFLEX
Covering rightside1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface rightside: Glued joints/smoothed

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Surface 1 Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish Generic product 8 mm 10.7 kg/m2 - - 04.011 91.139
Sheathed outside leftside 2nd layer Isolair Pavatex 60 mm 12 kg/m2 - - 10.009 91.051
Bond Stiff, execution of the prior art. - - - - - - -
Support Rib/bar Generic product, Origin mark Swiss wood 160 mm 7.5 kg/m2 60 mm 625 mm 07.002 91.047
Cavity dampening Isocell CPH Zellulosedämmstoffproduktion 160 mm 7.4 kg/m2 - - 10.010 91.046
Bond Rigid, execution of the prior art. - - - - - - -
Sheathed rightside 1st layer SWISS KRONO OSB/3 Willisauerstrasse 37, Na Hranici 2361/6, Swiss Krono.fr, Swiss Krono.pl, Swiss Krono.hu, Wittstocker Chaussee 1 15 mm 9 kg/m2 - - 07.013 91.145
Battens / profiles Wood lath transversely b=60mm Generic product, Origin mark Swiss wood 60 mm 2.8 kg/m2 60 mm 625 mm 07.011 91.052
Cavity dampening PAVAFLEX Pavatex 40 mm 2 kg/m2 - - 10.009 91.051
Covering rightside1st layer Gypsum fiber or hard gypsum board ≥ 1000kg/m³ Fermacell, Knauf, Rigips 12.5 mm 13.3 kg/m2 - - 03.007 91.063
Surface rightside Glued joints/smoothed Fermacell, Knauf, Rigips - - - - - -

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement Ift Rosenheim 22 21 25 33 39 37 39 38 45 47 51 54 59 62 71 78 80 77 75 80 76
Calculation Lignum/Kühn and Blickle 11 13 15 17 17 17 20 26 34 41 48 54 61 67 72 78 84 90 96 102 110 110

Airborne sound (R)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
70490.7
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
63277.4
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
7310.2
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
437.1
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
430.9
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
247.2
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
183
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
7.1
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
255.9
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
255.4
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
85.3
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
170.1
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.5
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
181.4
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
174.6
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
161.9
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
12.8
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
6.6
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
38.2
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
34.9
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
3.3
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
66
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
18
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)