LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly B0259

Lignum ID-№
B0259
Catalog number
B.3.01.IW 710B
Source of construction assembly
Tschopp, Year 2017
Base structure
BRESTA Solid Timber System
Sheathing
Sheathed on one side
Reference fire protection
Lignum Dok. 4.1 / Tabelle: 444
Construction height
270 mm
Weight
143 kg/m2
U-value
≈ 0.280 W/m2K
GWP
28.10 kg CO2-eq/m2
Type sound insulation
Calculation
Partition wall double shell consisting of a basic construction of solid timber without cavity insulation in the supporting structure. Sheathed in the interspace.Without covering. With cavity insulation between the wall panels.
Values of airborne sound insulation
Rw 65 dB
C -2 dB
C50-3150 dB

Graphic

Bond: Stiff, execution of the prior art.
Support leftside: Bresta Solid timber panel
Bond: Stiff, execution of the prior art.
Sheathed outside leftside 1st layer: Gypsum fiber board ≥ 1000kg/m³
Sheathed outside leftside 2nd layer: Gypsum fiber board ≥ 1000kg/m³
Intermediate insulation: Fiber insulation with 5≤ r ≤35 [kPa * s/m]
Air gap: Air
Sheathed far rightside 2nd layer: Gypsum fiber board ≥ 1000kg/m³
Sheathed outside rightside 1st layer: Gypsum fiber board ≥ 1000kg/m³
Bond: Stiff, execution of the prior art.
Support rightside: Bresta Solid timber panel
Bond: Stiff, execution of the prior art.

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Bond Stiff, execution of the prior art. - - - - - - -
Support leftside Bresta Solid timber panel Tschopp 80 mm 39.2 kg/m2 1000 mm 1000 mm 07.011.02 91.052
Bond Stiff, execution of the prior art. - - - - - - -
Sheathed outside leftside 1st layer Gypsum fiber board ≥ 1000kg/m³ Fermacell, Knauf, Rigips 15 mm 16 kg/m2 - - 03.007 91.063
Sheathed outside leftside 2nd layer Gypsum fiber board ≥ 1000kg/m³ Fermacell, Knauf, Rigips 15 mm 16 kg/m2 - - 03.007 91.063
Intermediate insulation Fiber insulation with 5≤ r ≤35 [kPa * s/m] Flumroc, Isover, Sager, Swisspor, Pavatex, Gutex, Isofloc, Schilliger Holz 40 mm 1.3 kg/m2 - - 10.008 91.173
Air gap Air - 10 mm - - - - -
Sheathed far rightside 2nd layer Gypsum fiber board ≥ 1000kg/m³ Fermacell, Knauf, Rigips 15 mm 16 kg/m2 - - 03.007 91.063
Sheathed outside rightside 1st layer Gypsum fiber board ≥ 1000kg/m³ Fermacell, Knauf, Rigips 15 mm 16 kg/m2 - - 03.007 91.063
Bond Stiff, execution of the prior art. - - - - - - -
Support rightside Bresta Solid timber panel Tschopp 80 mm 39.2 kg/m2 1000 mm 1000 mm 07.011.02 91.052
Bond Stiff, execution of the prior art. - - - - - - -

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Calculation Lignum/Kühn and Blickle 17 19 19 19 26 34 41 44 45 51 51 58 64 70 75 81 87 93 99 105 110 110

Airborne sound (R)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
61630.5
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
54388.8
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
7218
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
897.6
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
887.2
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
471.6
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
419.4
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
10.1
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
785.6
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
784.6
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
365.2
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
419.4
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.6
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
115.6
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
106.2
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
106.2
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
0
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
9.5
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
28.1
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
24.4
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
3.6
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
0
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
36.8
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)