LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly D0986

Lignum ID-№
D0986
Catalog number
D.1.02.AW320C
Source of construction assembly
Tschopp, Year 2017
Base structure
Stud
Type of facade
Ventilated facade and wall covering
Paneling
Without substructure, directly sheathed
Construction height
380 mm
Weight
77 kg/m2
U-value
≈ 0.165 W/m2K
GWP
17.30 kg CO2-eq/m2
Type sound insulation
Calculation
Outer wall consisting of a basic construction of stud with cavity insulation in the supporting structure with air flow resistivity [r] of 5≤ r ≤35 kPa s/m². Sheathed outside & interior, on the outside single sheathed, roomside single sheathed. Simple covering. Ventilated facade.
Values of airborne sound insulation
Rw 46 dB
C -1 dB
Ctr -7 dB

Graphic

Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Vapor-permeable water barrier
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Bresta Solid timber panel
Covering rightside1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Cover leftside 1st layer Wood cladding horizontal, closed Generic product, VSH, Label swiss wood 20 mm 9.8 kg/m2 - - 07.009.01 91.052
Battens / profiles (ventilation) Wood lath transversely b=60mm Generic product, Origin mark Swiss wood 40 mm 1.9 kg/m2 60 mm 625 mm 07.011 91.052
Sheathed outside leftside 1st layer Vapor-permeable water barrier Generic product 0.5 mm 0.2 kg/m2 - - 09.006 91.149
Bond Stiff, execution of the prior art. - - - - - - -
Support Rib/bar Generic product, Label swiss wood 220 mm 6.7 kg/m2 40 mm 640 mm 07.003.01 91.047
Cavity dampening Fiber insulation with 5≤ r ≤35 [kPa*s/m² Flumroc, Isover, Sager, Swisspor, Gutex, Isofloc, Schilliger Holz 220 mm 7 kg/m2 - - 10.008 91.173
Bond Stiff, execution of the prior art. - - - - - - -
Sheathed rightside 1st layer Bresta Solid timber panel Tschopp 87 mm 42.6 kg/m2 - - 07.011.02 91.052
Covering rightside1st layer Plasterboard type A Knauf, Rigips 12.5 mm 9.2 kg/m2 - - 03.008 91.064
Surface rightside Smoothed joints Knauf, Rigips - - - - 04.017 91.139

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Calculation Lignum/Kühn and Blickle 15 17 20 22 23 24 23 24 34 42 48 55 62 68 73 79 85 91 97 103 110 110

Airborne sound (R)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
41259.1
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
35856.6
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
5376.9
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
620
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
612.2
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
294.5
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
319.8
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
7.5
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
552.9
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
552.1
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
232.9
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
319.2
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.5
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
69.2
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
62.1
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
61.6
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
1
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
7.1
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
17.3
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
14.3
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
3
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
100.46666666666665
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
27.4
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)