Components

Construction assembly C0479

Lignum ID-№
C0479
Catalog number
C.3.02.KROE1.2
Source of construction assembly
Kronoply_Rosenheim_172 37203V01, Year 2009
Base structure
Solid wood panel
Sheathing
without sheathing
Paneling
Covering on both sides
Reference fire protection
Lignum Dok. 4.1, Tabelle: 44X
Construction height
245 mm
Weight
114 kg/m2
U-value
≈ 0.224 W/m2K
GWP
132.00 kg CO2-eq/m2
Type sound insulation
Measurement
Partition wall single shellconsisting of a basic construction ofsolid timber without cavity insulation in the supporting structure. without sheathing. Covering on both sides with cavity insulation.
Values of airborne sound insulation
Rw 68 dB
C -4 dB
C50-3150 -12 dB

Graphic

Surface leftside: Smoothed joints
Cover leftside 2nd layer: Rigidur H-Gipsfaserplatte
Cover leftside 1st layer: Rigidur H-Gipsfaserplatte
Battens / profiles: CW-wall profile b=50mm
Coupling: Air
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: no composite action
Support: SWISS KRONO MAGNUMBOARD OSB
Bond: no composite action
Coupling: Air
Battens / profiles: CW-wall profile b=50mm
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Covering rightside1st layer: Rigidur H-Gipsfaserplatte
Covering rightside 2nd layer: Rigidur H-Gipsfaserplatte
Surface rightside: Smoothed joints

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Surface leftside Smoothed joints Knauf, Rigips - - - - 04.017 91.139
Cover leftside 2nd layer Rigidur H-Gipsfaserplatte Rigips 12.5 mm 15 kg/m2 - - 03.007 91.063
Cover leftside 1st layer Rigidur H-Gipsfaserplatte Rigips 12.5 mm 15 kg/m2 - - 03.007 91.063
Battens / profiles CW-wall profile b=50mm Fermacell, Knauf, Rigips, Protektor 50 mm 1.1 kg/m2 50 mm 625 mm 06.011 91.143
Coupling Air - 10 mm - - - - -
Cavity dampening Fiber insulation with 5≤ r ≤35 [kPa*s/m² Flumroc, Isover, Sager, Swisspor, Gutex, Isofloc, Schilliger Holz 50 mm 1.6 kg/m2 - - 10.008 91.173
Bond no composite action - - - - - - -
Support SWISS KRONO MAGNUMBOARD OSB Willisauerstrasse 37, Wittstocker Chaussee 1 75 mm 49.5 kg/m2 1000 mm 1000 mm 07.013 91.145
Bond no composite action - - - - - - -
Coupling Air - 10 mm - - - - -
Battens / profiles CW-wall profile b=50mm Fermacell, Knauf, Rigips, Protektor 50 mm 1.1 kg/m2 50 mm 625 mm 06.011 91.143
Cavity dampening Fiber insulation with 5≤ r ≤35 [kPa*s/m² Flumroc, Isover, Sager, Swisspor, Gutex, Isofloc, Schilliger Holz 50 mm 1.6 kg/m2 - - 10.008 91.173
Covering rightside1st layer Rigidur H-Gipsfaserplatte Rigips 12.5 mm 15 kg/m2 - - 03.007 91.063
Covering rightside 2nd layer Rigidur H-Gipsfaserplatte Rigips 12.5 mm 15 kg/m2 - - 03.007 91.063
Surface rightside Smoothed joints Knauf, Rigips - - - - 04.017 91.139

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement Ift Rosenheim 19 28 28 36 47 57 60 56 60 65 69 72 72 74 74 71 73 74 74 76 74
Calculation Lignum/Kühn and Blickle 20 21 23 24 23 28 36 41 42 48 49 55 62 68 73 79 84 90 97 103 110 110

Airborne sound (R)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
339501
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
329466.4
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
10062.7
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
973.1
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
962.9
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
682.2
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
278.7
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
10.9
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
441.2
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
440.4
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
188.5
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
252
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.6
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
530.3
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
520.2
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
493.9
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
26.5
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
10.3
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
132
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
126.6
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
5.4
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
0
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
24.7
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)