LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly A0353

Lignum ID-№
A0353
Catalog number
A.2.02.L11
Source of construction assembly
Lignum, Year 2016
Base structure
Hollow box element
Paneling
Substructure with rubber-mounted hangers
Reference fire protection
Lignum Dok. 4.1 / Tabelle: 433
Construction height
550 mm
Weight
257 kg/m2
U-value
≈ 0.223 W/m2K
GWP
66.40 kg CO2-eq/m2
Type sound insulation
Verified calculation
Ceiling consisting of a basic construction of hollow box element, without sheathing, double ceiling covering. Substructure mounted with flexible hangers with cavity insulation with air flow resistivity [r] of 5≤ r ≤35 kPa s/m², without dampening in the supporting structure, with cavity insulation in the supporting structure. Without dampening on the supporting structure, with impact sound insulation with a dynamic stiffness [s'] of 6 MN/m³ and with cement screed.
Values of airborne sound insulation
Rw 73 dB
C -6 dB
C50-3150 -12 dB
Values of footfall sound insulation
Ln,w 39 dB
CI 3 dB
CI50-2500 14 dB

Graphic

On-lying material: Cement screed
Impact sound insulation: Glass wool with dynamic stiffness s' of ≤ 6 [MN/m³]
Sub-floor: Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³
Bond: Rigid, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Rigid, execution of the prior art.
Lower skin layer 1: Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: CD-ceiling profile b=60mm
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Ceiling covering 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Ceiling covering layer 2: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface / treatment: Glued joints/smoothed

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
On-lying material Cement screed Generic product 80 mm 176 kg/m2 - - 04.006 91.136
Impact sound insulation Glass wool with dynamic stiffness s' of ≤ 6 [MN/m³] Isover, Sager, Swisspor, Zisola 30 mm 2.4 kg/m2 - - 10.001.01 91.173
Sub-floor Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³ Willisauerstrasse 37, Pius Schuler, Stora Enso, Binderholz, Novatop, Pfleiderer, Schilliger Holz 25 mm 11.8 kg/m2 - - 07.001 91.048
Bond Rigid, execution of the prior art. - - - - - - -
Supporting structure Rib/bar Generic product, Label swiss wood 240 mm 15.1 kg/m2 80 mm 625 mm 07.003.01 91.047
Cavity dampening Fiber insulation with 5≤ r ≤35 [kPa*s/m² Flumroc, Isover, Sager, Swisspor, Gutex, Isofloc, Schilliger Holz 160 mm 4.5 kg/m2 - - 10.008 91.173
Bond Rigid, execution of the prior art. - - - - - - -
Lower skin layer 1 Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³ Willisauerstrasse 37, Pius Schuler, Stora Enso, Binderholz, Novatop, Pfleiderer, Schilliger Holz 25 mm 11.8 kg/m2 - - 07.001 91.048
Coupling Rubber mounted direct hanger b=60mm Ampack, Fermacell, Knauf, Rigips, Protektor 93 mm - - 729 mm - -
Battens / profiles CD-ceiling profile b=60mm Fermacell, Knauf, Rigips, Protektor 27 mm 1.1 kg/m2 60 mm 500 mm 06.011 91.143
Cavity dampening Fiber insulation with 5≤ r ≤35 [kPa*s/m² Flumroc, Isover, Sager, Swisspor, Gutex, Isofloc, Schilliger Holz 80 mm 2.6 kg/m2 - - 10.008 91.173
Ceiling covering 1st layer Gypsum fiber or hard gypsum board ≥ 1000kg/m³ Fermacell, Knauf, Rigips 15 mm 16 kg/m2 - - 03.007 91.063
Ceiling covering layer 2 Gypsum fiber or hard gypsum board ≥ 1000kg/m³ Fermacell, Knauf, Rigips 15 mm 16 kg/m2 - - 03.007 91.063
Surface / treatment Glued joints/smoothed Fermacell, Knauf, Rigips - - - - - -

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement Lignum Berechnung 23 31 36 45 52 61 70 78 87 95 103 110 110 110 110 110 110 110 110
Calculation Lignum/Kühn and Blickle 24 26 28 30 29 30 38 43 50 57 63 70 76 83 88 94 99 105 110 110 110 110
Impact sound (Ln) Measurement Lignum Berechnung 66 61 59 53 49 43 37 32 26 21 16 11 6 2 1 1 1 1 1
Calculation Lignum/Kühn and Blickle 57 58 59 60 64 66 61 59 55 51 48 44 41 37 35 32 30 27 24 21 15 10

Airborne sound (R)

Loading...

Impact sound (Ln)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
128011.2
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
114099.6
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
13834.1
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
698.7
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
681.3
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
480.9
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
202.4
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
17.4
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
460.8
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
460
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
265.7
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
193.1
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.9
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
239.7
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
223.3
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
214.1
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
9.2
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
16.5
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
66.4
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
60.9
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
5.4
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
67.10000000000001
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
18.3
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)