Construction assembly F0055

Lignum ID-№
F0055
Catalog number
F.3.01.DA150C
Source of construction assembly
Tschopp, Year 2017
Base structure
BRESTA Solid Timber System
Sheathing
without sheathing
Paneling
Without covering
Reference fire protection
VKF 14-15, Kap. 3.3 / Lignum Doc. 2.1, Kap. 6
Construction height
460 mm
Weight
117 kg/m2
U-value
≈ 0.121 W/m2K
GWP
143.30 kg CO2-eq/m2
Type sound insulation
Calculation
Flat roof / shed roof consisting of a basic construction of BRESTA Solid Timber System without cavity insulation in the supporting structure. without sheathing, . Without covering with insulation on top of the sub-floor.
Values of airborne sound insulation
Rw 44 dB
C -1 dB
Ctr -3 dB
Values of footfall sound insulation
Ln,w dB
CI dB
CI50-2500 dB

Graphic

Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Exterior insulation layer 1: Mineral wool
Separating layer / temporary roof: Vapor-permeable barrier
Bond: no composite action
Support: Bresta Solid timber panel

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Use and protection layer 2 Blowing clay Generic product 60 mm - - - 02.004 91.136
Use and protection layer 1 Protective layer Generic product 10 mm 9.2 kg/m2 - - 09.007 91.037
Seal Bituminous geomembrane Generic product 20 mm 22 kg/m2 - - 09.003 91.172
Exterior insulation layer 1 Mineral wool Generic product 200 mm 4 kg/m2 - - 10.008 91.173
Separating layer / temporary roof Vapor-permeable barrier Generic product 10 mm 3.9 kg/m2 - - 09.006 91.149
Bond no composite action - - - - - - -
Support Bresta Solid timber panel Tschopp 160 mm 78.4 kg/m2 1000 mm 1000 mm 07.011.02 91.052

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Calculation Lignum/Kühn and Blickle 27 30 32 35 38 40 42 42 44 47 50 53 55 57 58 58 58 67 76 83 92 100
Impact sound (Ln) Calculation Lignum/Kühn and Blickle 54 54 55 55 55 56 57 60 61 61 61 61 62 63 65 68 71 65 59 55 49 44

Airborne sound (R)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
212028.5
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
126519.3
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
85508.7
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
1429.4
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
1411.8
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
706.5
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
708.1
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
16.9
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
853.7
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
852.4
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
415.1
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
437.4
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
1
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
578.4
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
561.8
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
291.8
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
270.7
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
15.9
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
143.3
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
64
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
79.3
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
135.29999999999998
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
36.9
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)