LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly D1036

Lignum ID-№
D1036
Catalog number
D.3.03.AW445C
Source of construction assembly
Tschopp, Year 2017
Base structure
BRESTA Solid Timber System
Type of facade
Compact facade
Paneling
Without covering
Construction height
329 mm
Weight
104 kg/m2
U-value
≈ 0.174 W/m2K
GWP
51.50 kg CO2-eq/m2
Type sound insulation
Calculation
Outer wall consisting of a basic construction of BRESTA Solid Timber System without cavity insulation in the supporting structure. Sheathed outside & interior, on the outside single sheathed, roomside single sheathed. Without covering. Compact facade.
Values of airborne sound insulation
Rw 40 dB
C -1 dB
Ctr -4 dB

Graphic

Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Sheathed outside leftside 1st layer: Wood fiber board ≥ 180kg/m³
Bond: Stiff, execution of the prior art.
Support: Bresta Solid timber panel
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Surface 1 Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish Generic product 10 mm 13.3 kg/m2 - - 04.011 91.139
Sheathed outside leftside 1st layer Wood fiber board ≥ 180kg/m³ Gutex, Isover 220 mm 39.6 kg/m2 - - 10.009 91.051
Bond Stiff, execution of the prior art. - - - - - - -
Support Bresta Solid timber panel Tschopp 87 mm 42.6 kg/m2 1000 mm 1000 mm 07.011.02 91.052
Bond Stiff, execution of the prior art. - - - - - - -
Sheathed rightside 1st layer Plasterboard type A Knauf, Rigips 12.5 mm 9.2 kg/m2 - - 03.008 91.064
Surface rightside Smoothed joints Knauf, Rigips - - - - 04.017 91.139

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Calculation Lignum/Kühn and Blickle 22 24 27 30 32 35 37 36 39 42 44 47 50 52 52 52 53 62 70 77 87 95

Airborne sound (R)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
103629.8
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
91047.5
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
12895
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
949
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
939.3
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
486.5
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
453.8
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
12
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
711.5
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
710.6
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
277.8
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
432.8
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.8
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
240.7
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
229.5
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
208.5
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
21
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
11.2
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
51.5
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
46
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
5.7
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
134.5666666666667
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
36.7
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)