LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch
Values of airborne sound insulation | |
---|---|
Rw | 63 dB |
C | -3 dB |
C50-3150 | -12 dB |
Values of footfall sound insulation | |
---|---|
Ln,w | 52 dB |
CI | 1 dB |
CI50-2500 | 10 dB |
Layer | Product | Manufacturer | Thickness [mm] | Weight | Width (b) | Axial distance (e) | KBOB ID-№ Production | KBOB ID-№ Disposal |
---|---|---|---|---|---|---|---|---|
On-lying material | Floor heating system Therm38 longitudinal grooves | Fermacell, Knauf, Rigips | 23 mm | 28.3 kg/m2 | - | - | 03.007 | 91.063 |
Impact sound insulation | Wood fiber with dynamic stiffness s' of ≤ 30 [MN / m²] | Gutex, Isover | 22 mm | 3.5 kg/m2 | - | - | 10.009 | 91.051 |
Sub-floor | Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³ | Willisauerstrasse 37, Pius Schuler, Stora Enso, Binderholz, Novatop, Pfleiderer, Schilliger Holz | 25 mm | 11.8 kg/m2 | - | - | 07.001 | 91.048 |
Bond | Rigid, execution of the prior art. | - | - | - | - | - | - | - |
Supporting structure | Rib/bar | Generic product, Label swiss wood | 240 mm | 15.1 kg/m2 | 80 mm | 625 mm | 07.003.01 | 91.047 |
Cavity dampening | Fiber insulation with 5≤ r ≤35 [kPa*s/m² | Flumroc, Isover, Sager, Swisspor, Gutex, Isofloc, Schilliger Holz | 160 mm | 4.5 kg/m2 | - | - | 10.008 | 91.173 |
Bond | Rigid, execution of the prior art. | - | - | - | - | - | - | - |
Lower skin layer 1 | Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³ | Willisauerstrasse 37, Pius Schuler, Stora Enso, Binderholz, Novatop, Pfleiderer, Schilliger Holz | 25 mm | 11.8 kg/m2 | - | - | 07.001 | 91.048 |
Coupling | Rubber mounted direct hanger b=60mm | Ampack, Fermacell, Knauf, Rigips, Protektor | 93 mm | - | - | 1000 mm | - | - |
Battens / profiles | CD-ceiling profile b=60mm | Fermacell, Knauf, Rigips, Protektor | 27 mm | 1.1 kg/m2 | 60 mm | 500 mm | 06.011 | 91.143 |
Cavity dampening | Fiber insulation with 5≤ r ≤35 [kPa*s/m² | Flumroc, Isover, Sager, Swisspor, Gutex, Isofloc, Schilliger Holz | 80 mm | 2.6 kg/m2 | - | - | 10.008 | 91.173 |
Ceiling covering 1st layer | Plasterboard type A | Knauf, Rigips | 15 mm | 11 kg/m2 | - | - | 03.008 | 91.064 |
Ceiling covering layer 2 | Plasterboard type A | Knauf, Rigips | 15 mm | 11 kg/m2 | - | - | 03.008 | 91.064 |
Surface / treatment | Smoothed joints | Knauf, Rigips | - | - | - | - | 04.017 | 91.139 |
Color | Type | 25 | 32 | 40 | 50 | 63 | 80 | 100 | 125 | 160 | 200 | 250 | 315 | 400 | 500 | 630 | 800 | 1000 | 1250 | 1600 | 2000 | 2500 | 3150 | 4000 | 5000 | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airborne sound (R) | Measurement | Lignum Berechnung | 13 | 22 | 30 | 36 | 38 | 43 | 49 | 59 | 68 | 78 | 86 | 93 | 102 | 109 | 110 | 110 | 110 | 110 | 110 | |||||
Calculation | Lignum/Kühn and Blickle | 15 | 17 | 19 | 21 | 22 | 21 | 27 | 32 | 40 | 47 | 53 | 60 | 66 | 72 | 78 | 84 | 89 | 95 | 101 | 107 | 110 | 110 | |||
Impact sound (Ln) | Measurement | Lignum Berechnung | 75 | 70 | 65 | 62 | 63 | 61 | 58 | 51 | 45 | 38 | 33 | 29 | 23 | 19 | 14 | 9 | 4 | 1 | 1 | |||||
Calculation | Lignum/Kühn and Blickle | 66 | 67 | 68 | 69 | 71 | 75 | 72 | 70 | 65 | 61 | 58 | 54 | 51 | 47 | 45 | 42 | 40 | 37 | 34 | 31 | 25 | 20 |
bSDD Properties | ||||||||
---|---|---|---|---|---|---|---|---|
mm | Indicators | Modules | ||||||
Values / m2 | ||||||||
+
|
Environmental impact points (UBP)
|
100586.3
|
UBP'21/m2
|
A1-A3 + C1-C4
|
||||
|
┣
|
Environmental impact points from production (UBP_pro)
|
92458.6
|
UBP'21/m2
|
A1-A3
|
|||
|
┗
|
Environmental impact points from disposal (UBP_dis)
|
8189.7
|
UBP'21/m2
|
C1-C4
|
|||
+
|
Total primary energy (PE_T)
|
692.5
|
kWh oil-eq/m2
|
A1-A3 + C1-C4
|
||||
|
┣
|
Primary energy from production (PE_pro)
|
683.3
|
kWh oil-eq/m2
|
A1-A3
|
|||
|
┃
|
┣
|
Primary energy production, energetically consumed (PE_E_pro)
|
462.8
|
kWh oil-eq/m2
|
A1-A3
|
||
|
┃
|
┗
|
Primary energy production, materially bound (PE_M_pro)
|
222.5
|
kWh oil-eq/m2
|
A1-A3
|
||
|
┗
|
Primary energy from disposal (PE_dis)
|
9.5
|
kWh oil-eq/m2
|
C1-C4
|
|||
+
|
Renewable primary energy (PE_RT)
|
475.5
|
kWh oil-eq/m2
|
A1-A3 + C1-C4
|
||||
|
┣
|
Renewable primary energy from production (PE_RT_pro)
|
475
|
kWh oil-eq/m2
|
A1-A3
|
|||
|
┃
|
┣
|
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
|
262.5
|
kWh oil-eq/m2
|
A1-A3
|
||
|
┃
|
┗
|
Renewable primary energy from production, materially bound (PE_RM_pro)
|
211.3
|
kWh oil-eq/m2
|
A1-A3
|
||
|
┗
|
Renewable primary energy from disposal (PE_RT_dis)
|
0.6
|
kWh oil-eq/m2
|
C1-C4
|
|||
+
|
Total use of non- renewable primary energy resources (PE_NRT)
|
218.9
|
kWh oil-eq/m2
|
A1-A3 + C1-C4
|
||||
|
┣
|
Primary energy not renewable from manufacturing (PE_NRT_pro)
|
210
|
kWh oil-eq/m2
|
A1-A3
|
|||
|
┃
|
┣
|
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
|
199
|
kWh oil-eq/m2
|
A1-A3
|
||
|
┃
|
┗
|
Primary energy not renewable from production, materially bound (PE_NRM_pro)
|
11.1
|
kWh oil-eq/m2
|
A1-A3
|
||
|
┗
|
Primary energy not renewable from disposal (PE_NRT_dis)
|
8.9
|
kWh oil-eq/m2
|
C1-C4
|
|||
+
|
Total greenhouse gas emissions (GWP_total)
|
49.9
|
kg CO2/m2
|
A1-A3 + C1-C4
|
||||
|
┣
|
Greenhouse gas emissions from manufacturing (GWP_pro)
|
46.2
|
kg CO2/m2
|
A1-A3
|
|||
|
┗
|
Greenhouse gas emissions from waste disposal (GWP_dis)
|
3.7
|
kg CO2/m2
|
C1-C4
|
|||
|
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
|
73.7
|
kg CO2/m2
|
B1-B7
|
||||
|
Biogenic carbon storage (bio-C) (Not included in GWP)
|
20.1
|
kg C/m2
|
B1-B7
|
||||
⇒ Advantages of the life cycle assessment outside the system boundary (module D) |