LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly F0159

Lignum ID-№
F0159
Catalog number
F.1.01.PB30
Source of construction assembly
PB 18-002112-PR01 PB 30-F01-04-de-01, Year 2018
Base structure
Ribs
Sheathing
Sheathed left & rightside
Paneling
Without covering
Reference fire protection
VKF Brandschutzanwendung Nr. 15421
Construction height
495 mm
Weight
278 kg/m2
U-value
≈ 0.166 W/m2K
GWP
80.20 kg CO2-eq/m2
Type sound insulation
Measurement
Flat roof / shed roof consisting of a basic construction of ribs without cavity insulation in the supporting structure. Sheathed left & rightside, leftside single sheathed rightside single sheathed. Without covering with insulation on top of the sub-floor.
Values of airborne sound insulation
Rw 57 dB
C -2 dB
Ctr -7 dB
Values of footfall sound insulation
Ln,w 40 dB
CI 0 dB
CI50-2500 dB

Graphic

Use and protection layer 3: Concrete panels
Use and protection layer 1: Edelsplitt 2/5
Separating layer: Lamination of 3-ply roof membrane made of polypropylene, Monier GmbH
Under the roof: Sealing sheet rubber (EPDM)
Exterior insulation layer 2: Expanded polystyrene (EPS)
Sheathed above 1st layer: OSB / 3 slabs for load-bearing purposes for use in damp conditions
Support: Ribs Lignotrend Q3
Dampening in supporting structure: Edelsplitt 2/5
Lower skin layer 1: Your acoustic decking to Lignotrend Q3 Classic slotting 4/12mm

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Use and protection layer 3 Concrete panels Generic product 40 mm 94.8 kg/m2 - - 02.007 91.136
Use and protection layer 1 Edelsplitt 2/5 Generic product 30 mm 42 kg/m2 - - 03.011 91.062
Separating layer Lamination of 3-ply roof membrane made of polypropylene, Monier GmbH Knauf 5 mm 1.9 kg/m2 - - 09.007 91.037
Under the roof Sealing sheet rubber (EPDM) Generic product 2.5 mm 2.8 kg/m2 - - 09.004 91.147
Exterior insulation layer 2 Expanded polystyrene (EPS) Swisspor, Sager 200 mm 3 kg/m2 - - 10.004 91.151
Sheathed above 1st layer OSB / 3 slabs for load-bearing purposes for use in damp conditions Generic product, Willisauerstrasse 37, Sonae Arauco SA, Egger, Norbord Europe Ltd. 22 mm 14.3 kg/m2 - - 07.013 91.145
Support Ribs Lignotrend Q3 Lignotrend 164 mm 43 kg/m2 71.7 mm 134 mm 07.011 91.052
Dampening in supporting structure Edelsplitt 2/5 Generic product 95 mm 61.9 kg/m2 - - 03.011 91.062
Lower skin layer 1 Your acoustic decking to Lignotrend Q3 Classic slotting 4/12mm Lignotrend 32 mm 15 kg/m2 - - 07.011.01 91.052

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement Ift Rosenheim 35 36 46 48 44 39 37 42 53 53 54 56 61 69 76 81 83 81 83 86 86
Calculation Lignum/Kühn and Blickle 13 16 18 21 24 26 28 28 30 33 36 39 41 43 44 44 44 53 62 69 78 86
Impact sound (Ln) Measurement Ift Rosenheim 63 62 52 51 46 46 46 40 33 40 42 42 35 34 25 26 16 21 16 9 9
Calculation Lignum/Kühn and Blickle 68 68 69 69 69 70 71 74 75 75 75 75 76 77 79 82 85 79 73 69 63 58

Airborne sound (R)

Loading...

Ecological indicators according to the KBOB life cycle assessment data in the construction sector KBOB / ecobau / IPB 2009/1:2022, Version 6
(For the life cycle phases production and disposal, excluding the construction phase (Modules A4, A5) and the use phase (Module B), especially replacement (Module B4) or amortization periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
130536
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
95424
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
35098
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
792.90
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
776.70
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
323.50
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
452.30
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
16.20
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
477.50
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
476.40
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
104.90
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
371.60
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.80
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
314.90
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
299.30
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
218.90
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
80.60
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
15.40
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
80.20
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
52.10
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
28.10
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
119.17
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
32.50
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)