LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly C0468

Lignum ID-№
C0468
Catalog number
C.3.01.KROB2.1
Source of construction assembly
Kronoply GmbH, Year 2009
Base structure
Solid wood panel
Sheathing
Sheathed on one side
Paneling
Without covering
Reference fire protection
Lignum Dok. 4.1, Tabelle: 44X
Construction height
112 mm
Weight
81 kg/m2
U-value
≈ 0.463 W/m2K
GWP
45.40 kg CO2-eq/m2
Type sound insulation
Verified calculation
Partition wall single shellconsisting of a basic construction ofsolid timber without cavity insulation in the supporting structure. Sheathed on one side, leftside single sheathed. Without covering.
Values of airborne sound insulation
Rw 39 dB
C dB
C50-3150 dB

Graphic

Surface leftside: Smoothed joints
Sheathed leftside 1st layer: Rigidur H-Gipsfaserplatte
Bond: Stiff, execution of the prior art.
Support: SWISS KRONO MAGNUMBOARD OSB

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Surface leftside Smoothed joints Knauf, Rigips - - - - 04.017 91.139
Sheathed leftside 1st layer Rigidur H-Gipsfaserplatte Rigips 12.5 mm 15 kg/m2 - - 03.007 91.063
Bond Stiff, execution of the prior art. - - - - - - -
Support SWISS KRONO MAGNUMBOARD OSB Willisauerstrasse 37, Wittstocker Chaussee 1 100 mm 66 kg/m2 1000 mm 1000 mm 07.013 91.145

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Calculation Lignum/Kühn and Blickle 23 25 28 31 33 36 38 37 34 37 33 36 39 41 42 41 42 51 59 67 76 84

Airborne sound (R)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
81075
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
72867
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
8068.5
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
764.6
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
756.8
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
382.5
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
371.6
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
8.1
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
546.6
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
545.9
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
210
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
335.9
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.5
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
215.9
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
208.1
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
173.1
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
35.3
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
7.6
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
45.4
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
39.9
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
5.5
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
0
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
30
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)