LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly A2730

Lignum ID-№
A2730
Catalog number
A.4.01.24-003699-PR01(PB06-F03-04-de-01)
Source of construction assembly
Swiss Krono, Year 2024
Base structure
Timber-concrete composite floor (tccf)
Paneling
Without covering
Reference fire protection
Lignum Dok. 4.1 / Tabelle: 437
Construction height
222 mm
Weight
291 kg/m2
U-value
≈ 0.409 W/m2K
GWP
83.20 kg CO2-eq/m2
Type sound insulation
Measurement
Ceiling consisting of a basic construction of timber-concrete composite floor (tccf), without sheathing, without ceiling covering, without dampening in the supporting structure, without cavity insulation in the supporting structure. Without dampening on the supporting structure, without impact sound insulation and without screed.
Values of airborne sound insulation
Rw dB
C dB
C50-3150 dB
Values of footfall sound insulation
Ln,w 48 dB
CI 1 dB
CI50-2500 1 dB

Graphic

Flooring: Tufted rug synthetic fiber
Sub-floor: Concrete reinforced with steel 1%
Bond: Stiff, execution of the prior art.
Supporting structure: SWISS KRONO MAGNUMBOARD OSB

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Flooring Tufted rug synthetic fiber Generic product 7.5 mm 2 kg/m2 - - 11.024 91.019
Sub-floor Concrete reinforced with steel 1% Generic product 90 mm 207 kg/m2 - - 01.042 91.061
Bond Stiff, execution of the prior art. - - - - - - -
Supporting structure SWISS KRONO MAGNUMBOARD OSB Willisauerstrasse 37, Wittstocker Chaussee 1 125 mm 82.5 kg/m2 1000 mm 1000 mm 07.013 91.145

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Calculation Lignum/Kühn and Blickle 29 32 34 37 40 42 44 44 46 49 52 55 57 59 60 60 60 69 78 85 94 103
Impact sound (Ln) Measurement Ift Rosenheim 51 50 53 55 55 55 57 53 52 49 43 39 33 28 28 29 22 16 16 17 11
Calculation Lignum/Kühn and Blickle 52 52 53 53 53 54 55 58 59 59 59 59 60 61 63 66 69 63 57 53 47 41

Airborne sound (R)

Loading...

Impact sound (Ln)

Loading...

Ecological indicators according to the KBOB life cycle assessment data in the construction sector KBOB / ecobau / IPB 2009/1:2022, Version 6
(For the life cycle phases production and disposal, excluding the construction phase (Modules A4, A5) and the use phase (Module B), especially replacement (Module B4) or amortization periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
143444
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
127466
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
15792
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
1016.90
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
998.00
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
530.20
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
464.60
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
19.20
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
701.10
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
699.90
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
280.00
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
419.90
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.90
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
313.30
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
294.90
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
251.10
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
44.20
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
18.30
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
83.20
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
74.00
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
9.10
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
134.20
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
36.60
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)