Construction assembly A0234

Lignum ID-№
A0234
Catalog number
A.1.03.A53
Source of construction assembly
Lignum, Year 2016
Base structure
Ribs / joists
Paneling
Without covering
Reference fire protection
Lignum Dok. 4.1 / Tabelle: 431 (Balken) oder 432 (Rippen)
Construction height
410 mm
Weight
158 kg/m2
U-value
≈ 0.415 W/m2K
GWP
32.90 kg CO2-eq/m2
Type sound insulation
Verified calculation
Ceiling consisting of a basic construction of ribs / joists, without sheathing, without ceiling covering, without dampening in the supporting structure, without cavity insulation in the supporting structure. With dampening on the supporting structure, with impact sound insulation with a dynamic stiffness [s'] of 30 MN/m³ and with dry screed.
Values of airborne sound insulation
Rw 53 dB
C -3 dB
C50-3150 -3 dB
Values of footfall sound insulation
Ln,w 62 dB
CI 1 dB
CI50-2500 1 dB

Graphic

On-lying material: Floor heating system Therm38 longitudinal grooves
Impact sound insulation: Wood fiber with dynamic stiffness s' of ≤ 30 [MN / m²]
Dampening on Supporting structure: Dampening gravel ≤ 1400 kg/m³
Sub-floor: Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
On-lying material Floor heating system Therm38 longitudinal grooves Fermacell, Knauf, Rigips 23 mm 28.3 kg/m2 - - 03.007 91.063
Impact sound insulation Wood fiber with dynamic stiffness s' of ≤ 30 [MN / m²] Gutex, Isover 22 mm 3.5 kg/m2 - - 10.009 91.051
Dampening on Supporting structure Dampening gravel ≤ 1400 kg/m³ Fermacell, Zisola 60 mm 84 kg/m2 - - 03.011 91.062
Sub-floor Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³ Willisauerstrasse 37, Pius Schuler, Stora Enso, Binderholz, Novatop, Pfleiderer, Schilliger Holz 25 mm 11.8 kg/m2 - - 07.001 91.048
Bond Stiff, execution of the prior art. - - - - - - -
Supporting structure Rib/bar Generic product, Label swiss wood 280 mm 30.7 kg/m2 140 mm 625 mm 07.003.01 91.047

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement Lignum Berechnung 26 28 30 32 30 31 37 43 49 55 60 64 69 73 78 83 88 95 102
Calculation Lignum/Kühn and Blickle 23 26 28 31 34 36 38 37 40 43 46 48 51 53 54 54 54 63 72 79 88 96
Impact sound (Ln) Measurement Lignum Berechnung 63 64 65 66 71 73 70 67 64 61 59 58 56 55 53 51 49 45 41
Calculation Lignum/Kühn and Blickle 58 58 59 59 59 60 61 64 65 65 65 66 66 67 69 72 75 69 64 59 53 47

Airborne sound (R)

Loading...

Impact sound (Ln)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
67864.9
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
58486.1
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
9410.2
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
581.4
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
570
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
329.2
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
241.7
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
11.7
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
430.9
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
430.2
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
196.6
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
233.1
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.6
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
151.5
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
140.5
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
132.2
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
8.4
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
11
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
32.9
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
28.9
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
4.1
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
79.2
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
21.6
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)