LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly A2176

Lignum ID-№
A2176
Catalog number
A.3.01.DE310B
Source of construction assembly
Tschopp, Year 2017
Base structure
BRESTA Solid Timber System
Paneling
Without covering
Reference fire protection
Lignum Dok. 4.1 / Tabelle: 434
Construction height
322 mm
Weight
103 kg/m2
U-value
≈ 0.161 W/m2K
GWP
30.00 kg CO2-eq/m2
Type sound insulation
Calculation
Ceiling consisting of a basic construction of BRESTA Solid Timber System, without sheathing, without ceiling covering, without dampening in the supporting structure, without cavity insulation in the supporting structure. Without dampening on the supporting structure, with impact sound insulation with a dynamic stiffness [s'] of 1.3 MN/m³ and with dry screed.
Values of airborne sound insulation
Rw 49 dB
C -3 dB
C50-3150 0 dB
Values of footfall sound insulation
Ln,w 65 dB
CI 0 dB
CI50-2500 4 dB

Graphic

On-lying material: OSB3 panel
Impact sound insulation: Glass wool with dynamic stiffness s' of ≤ 9 [MN/m³]
Bond: no composite action
Supporting structure: Bresta Solid timber panel

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
On-lying material OSB3 panel Willisauerstrasse 37, Pius Schuler, Stora Enso, Binderholz, Novatop, Pfleiderer 22 mm 14.3 kg/m2 - - 07.013 91.145
Impact sound insulation Glass wool with dynamic stiffness s' of ≤ 9 [MN/m³] Isover, Sager, Swisspor, Zisola 140 mm 11.2 kg/m2 - - 10.001.01 91.173
Bond no composite action - - - - - - -
Supporting structure Bresta Solid timber panel Tschopp 160 mm 78.4 kg/m2 1000 mm 1000 mm 07.011.02 91.052

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Calculation Lignum/Kühn and Blickle 27 29 32 35 37 40 42 41 44 46 49 52 55 57 57 57 58 67 75 82 91 100
Impact sound (Ln) Calculation Lignum/Kühn and Blickle 54 55 55 55 56 56 57 61 61 62 62 62 62 63 66 69 71 65 60 56 49 44

Airborne sound (R)

Loading...

Impact sound (Ln)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
68937
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
61109.4
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
7746.4
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
1055.5
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
1044.7
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
548.1
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
499.9
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
10.5
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
926.1
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
925
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
432.8
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
492.2
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.7
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
132.8
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
122.9
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
115.3
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
7.7
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
9.8
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
30
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
25.2
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
4.9
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
152.9
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
41.7
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)