LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly C0101

Lignum ID-№
C0101
Catalog number
C.1.03.M11
Source of construction assembly
Lignum, Year 2016
Base structure
Stud
Sheathing
Sheathed on one side
Paneling
Covering on one side
Reference fire protection
Lignum Dok. 4.1, Tabelle: 441
Construction height
250 mm
Weight
56 kg/m2
U-value
≈ 0.189 W/m2K
GWP
21.40 kg CO2-eq/m2
Type sound insulation
Verified calculation
Partition wall single shellconsisting of a basic construction ofstud with cavity insulation in the supporting structure with air flow resistivity [r] of 5≤ r ≤35 kPa s/m². Sheathed on one side, leftside double sheathed. Covering on one side with cavity insulation.
Values of airborne sound insulation
Rw 64 dB
C -4 dB
C50-3150 -12 dB

Graphic

Surface leftside: Smoothed joints
Sheathed leftside 2nd layer: Plasterboard type A
Sheathed leftside 1st layer: OSB panel
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: no composite action
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath b=60mm
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Covering rightside1st layer: Plasterboard type A
Covering rightside 2nd layer: Plasterboard type A
Surface rightside: Smoothed joints

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Surface leftside Smoothed joints Knauf, Rigips - - - - 04.017 91.139
Sheathed leftside 2nd layer Plasterboard type A Knauf, Rigips 15 mm 11 kg/m2 - - 03.008 91.064
Sheathed leftside 1st layer OSB panel Willisauerstrasse 37, Pius Schuler, Stora Enso, Binderholz, Novatop, Pfleiderer 15 mm 9.8 kg/m2 - - 07.013 91.145
Bond Stiff, execution of the prior art. - - - - - - -
Support Rib/bar Generic product, Origin mark Swiss wood 140 mm 6.6 kg/m2 60 mm 625 mm 07.002 91.047
Cavity dampening Fiber insulation with 5≤ r ≤35 [kPa*s/m² Flumroc, Isover, Sager, Swisspor, Gutex, Isofloc, Schilliger Holz 140 mm 4.5 kg/m2 - - 10.008 91.173
Bond no composite action - - - - - - -
Coupling Rubber mounted direct hanger b=60mm Ampack, Fermacell, Knauf, Rigips, Protektor 20 mm - - 625 mm - -
Battens / profiles Wood lath b=60mm Generic product, Origin mark Swiss wood 30 mm 1.4 kg/m2 60 mm 625 mm 07.011 91.052
Cavity dampening Fiber insulation with 5≤ r ≤35 [kPa*s/m² Flumroc, Isover, Sager, Swisspor, Gutex, Isofloc, Schilliger Holz 40 mm 1.3 kg/m2 - - 10.008 91.173
Covering rightside1st layer Plasterboard type A Knauf, Rigips 15 mm 11 kg/m2 - - 03.008 91.064
Covering rightside 2nd layer Plasterboard type A Knauf, Rigips 15 mm 11 kg/m2 - - 03.008 91.064
Surface rightside Smoothed joints Knauf, Rigips - - - - 04.017 91.139

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Calculation Lignum/Kühn and Blickle 3 2 5 14 22 29 35 37 44 50 56 62 69 75 80 86 91 98 104 110 110 110

Airborne sound (R)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
41798.9
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
36722.7
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
5068.3
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
326
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
319.9
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
154.7
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
164.8
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
6.1
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
228.8
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
228.3
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
69.4
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
158.9
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.4
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
96.8
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
91
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
85.3
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
5.8
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
5.7
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
21.4
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
19
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
2.4
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
0
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
14.5
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)